Alnor DV-PP-100-270 Скачать руководство пользователя страница 2

Safety warnings

• 

Make sure that the power supply has been disconnected before performing the installation or electrical connection of the 

appliance.

• 

Installation, electrical connections and settings must be carried out by a qualified person in line with local regulations.

• 

If these installation instructions are not followed the product may be damaged.

• 

For optimal performance, the appliance must be installed correctly (installation of the unit, ducts and air replacement 

inlets).

• 

This extractor fan is designed for the ventilation of households or similar premises. Do not use for any purpose other than 

that for which it was designed.

• 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.

• 

Cleaning and user maintenance shall not be made by children without supervision.

• 

The fan is to be installed so that the blades are more than 2,3 m above the floor.

• 

This extractor fan does not produce radio/television interference (Directive 2004/108/EC).

• 

Prior to piping installation, consult the municipal by-laws on air outlets and request permission from the person responsi-

ble for the building.

• 

Precaution must be taken to avoid the backflow of gases into the room from the open gas pipe or from other open-flame 

devices.

• 

The room must have adequate ventilation if this appliance is used simultaneously with other appliances that run on gas or 

other fuels.

• 

Do not install the exhaust conduit (A, B) of the extractor fan to a chimney flume, ventilation pipes, hot air ducts or ducts 

used to evacuate fumes from appliances that run on gas or other fuels.

• 

DO NOT install this product in areas with the follow characteristics:

• 

Excess of oil or grease.

• 

Areas with corrosive, explosive or flammable liquids, gases or vapours.

• 

Areas with temperatures higher than 60 °C or lower than -5 °C.

• 

Areas exposed to the environment (rain, sun, snow, etc.)

• 

Areas with possible obstacles that obstruct the access to the fan.

• 

The product and its parts must not be submerged in water or other liquids.

• 

The IP rating is only valid if the installation of the appliance complies with what is indicated in this manual.

• 

The manufacturer declines all responsibility for personal injury or damage to animals or objects caused by inappropriate 

use of the appliance according to the warnings for installation, use and maintenance described in this instruction manual.

• 

After finishing the installation these instructions should be given to the owner/user of the appliance.

Assembly

• 

Before starting the installation, check that the propeller is not deformed or damaged, that it can turn freely, and that no 

foreign body is lodged inside the outer casing.

• 

This type of tubular extractor is designed to work within any section of the air exhaust duct (rigid or flexible) in either a 

horizontal or a vertical position.

• 

The appliance shall be installed according to the attached graphic documentation (see fig. 1 and 2)

• 

Loosen the 2 screws (D) and lift the flanges (E). Take the casing assembly (F) out of its housing.

• 

Place the b openings (G) in the place where you want to install the extractor (wall or ceiling) and mark 

the holes (H).

• 

Make four holes with a suitable drill bit and secure the bracket using the plugs and screws included with the 

appliance.

• 

Is recommended that you place the appliance at a distance equal to or greater than one metre from the bend or 

the closest suction-expulsion opening.

• 

Join the suction (A) and expulsion (B) conduits to the nozzles (I) by flanges or resistant adhesive tape

• 

It is important that the diameter of the tube should be equal to the diameter of the openings to ensure efficient operation 

of the appliance.

• 

• Replace the casing (F) in its housing in such a way that the air circulation direction indicated by the arrows (J) and the 

cable outlet direction are as desired.

• 

Close the flanges (E) and tighten the screws (D)

• 

Whether the assembly is done with an individual exhaust tube or with a direct outlet, air grilles must be installed that 

comply with national safety requirements for preventingaccess to the fan blades Make sure that there is no obstacle bloc-

king the flow of air.

c

ALNOR® 

ventilation systems

is a legally protected trademark and technical patent. All rights reserved.

2

w

w

w

.v

ent

ila

tio

n-

al

no

r.co

.u

k

Manual - Duct fans

DV-PP

Содержание DV-PP-100-270

Страница 1: ...User s Manual In line Duct Fans DV PP 100 130 DV PP 100 270 DV PP 125 320 DV PP 150 560 DV PP 160 560 DV PP 200 910 Models...

Страница 2: ...ruct the access to the fan The product and its parts must not be submerged in water or other liquids The IP rating is only valid if the installation of the appliance complies with what is indicated in...

Страница 3: ...H I J A O F Fig 1 Fig 2 Assembly and diassembly sequence 3 ALNOR ventilation systems is a legally protected trademark and technical patent All rights reserved www ventilation alnor co uk Manual Duct...

Страница 4: ...30 98 177 238 100 89 100 20 DV PP 100 270 98 230 310 130 115 170 20 DV PP 125 320 122 217 262 100 100 168 21 DV PP 150 560 147 244 293 130 115 192 21 DV PP 160 560 157 244 313 130 115 192 21 DV PP 200...

Страница 5: ...w the power supply wires to pass through The power supply cable must be placed so that no liquid or vapour can enter the appliance along it If this were not possible the cable entry should be sealed a...

Страница 6: ...mic performance and motor damage Motor bearings do not need maintenance Once maintenance is complete refit the reducer pipes and casing assembly Always demand original spare parts for repairs The symb...

Страница 7: ...130 C DV PP 100 270 30 270 B DV PP 125 230 32 365 B DV PP 150 560 33 595 C DV PP 160 560 33 595 C DV PP 200 910 39 910 B The manufacturer reserves the right to make any technological improvement or m...

Отзывы: