SERVICE AND REPAIR 

Service and Repair 

Please return your Product Registration Card immediately. This 
allows us send you service reminders, special offers, and important 
information about your product.  
Before sending your instrument for calibration or repair, you 
should call Customer Service. The Service Department will 
provide you with the cost of service or calibration, Return Material 
Authorization (RMA) number, and shipping instructions. 
Please have the following information available when you call: 

 Owner’s name, address, and phone number, 

 Billing address, 

if different and applicable, 

 Instrument name or model, 

 Serial 

number, 

 Date of purchase, 

 Where purchased 

TSI recommends that you keep a “calibration log” and keep all 
records of service on your instrument.

  

Instructions for Return 

Send the instrument prepaid. Securely package your instrument in 
a strong container surrounded by at least two inches (5 cm) of 
suitable shock-absorbing material. Include the Purchase Order 
showing instrument model number, cost of service and/or 
calibration, and the RMA number. Mark the outside of the shipping 
container with the RMA number. This will expedite processing of 
your instrument when we receive it. 

Damaged in Transit 

All orders are carefully packed for shipment. On receipt, if the 
shipping container appears to have been damaged during shipment, 
the instrument should be thoroughly inspected. The delivering 
carrier’s papers should be signed noting the apparent damage. DO 
NOT DISCARD THE BOX. 
If the instrument itself has been damaged, a claim should be 
promptly filed against the carrier by the customer. The selling agent 
will assist the customer by supplying all pertinent shipping 
information; however, the claim must be filed by the insured. If the 
instrument is damaged beyond use, a new order should be placed 
with TSI while awaiting reimbursement from the carrier for the 
damaged instrument.  
Call TSI directly for assistance if necessary.

 

LIMITATION OF WARRANTY AND LIABILITY 

Seller warrants that this product, under normal use and service as 
described in the operator's manual, shall be free from defects in 
workmanship and material for a period of twenty-four (24) months, or the 
length of time specified in operator's manual, from the date of shipment to 
the customer. This limited warranty is subject to the following exclusions: 
a.  Batteries and certain other components when indicated in 
specifications are warranted for a period of 90 days from the date of 
shipment to the customer. 
b.  With respect to any repair services rendered, Seller warrants that the 
parts repaired or replaced will be free from defects in workmanship and 
material, under normal use, for a period of 90 days from the date of 
shipment to the customer. 
c.  Seller does not provide any warranty on finished goods manufactured 
by others. Only the original manufacturer's warranty applies. 
d.  Unless specifically authorized in a separate writing by Seller, Seller 
makes no warranty with respect to, and shall have no liability in connection 
with, any goods which are incorporated into other products or equipment 
by the Buyer. All goods returned under warranty shall be at the Buyer’s risk 
of loss, Seller’s factory prepaid, and will be returned at Seller’s risk of loss, 
Buyer’s factory prepaid. 
The foregoing is IN LIEU OF all other warranties and is subject to the 
conditions and LIMITATIONS stated herein. NO OTHER EXPRESS OR 
IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR 
MERCHANTABILITY IS MADE. 
THE EXCLUSIVE REMEDY OF THE USER OR PURCHASER, AND THE 
LIMIT OF THE LIABILITY OF SELLER FOR ANY AND ALL LOSSES, 
INJURIES, OR DAMAGES IN CONNECTION WITH THIS PRODUCT 
(INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, STRICT 
LIABILITY, OTHER TORT, OR OTHERWISE) SHALL BE THE RETURN 
OF THE PRODUCT TO THE FACTORY OR DESIGNATED LOCATION 
AND THE REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION 
OF SELLER, THE REPAIR OR REPLACEMENT OF THE PRODUCT. IN 
NO EVENT SHALL SELLER BE LIABLE FOR ANY SPECIAL, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES. SELLER SHALL NOT 
BE RESPONSIBLE FOR INSTALLATION, DISMANTLING, REASSEMBLY 
OR REINSTALLATION COSTS OR CHARGES. NO ACTION, 
REGARDLESS OF FORM, MAY BE BROUGHT AGAINST THE SELLER 
MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS 
ACCRUED. 
The purchaser and all users are deemed to have accepted the terms of 
this LIMITATION OF WARRANTY AND LIABILITY, which contains the 
complete and exclusive limited warranty of Seller. This LIMITATION OF 
WARRANTY AND LIABILITY may not be amended or modified nor may 
any of its terms be waived except by a writing signed by an authorized 
representative of Seller. 

Service Policy 

Knowing that inoperative or defective instruments are as detrimental to TSI 
as they are to our customers, our service policy is designed to give prompt 
attention to any problems. If any malfunction is discovered, please contact 
your nearest sales office or representative, or call Customer Service 
department at (800) 424-7427 (USA) and (1) 651-490-2811 (International).

 

-14- 

Содержание 9850

Страница 1: ...______________________________ _________________________________________ _________________________________________ TSI Incorporated Alnor Products 500 Cardigan Road Shoreview MN 55126 USA Toll Free 800 424 7427 Telephone 651 490 2811 August 2002 Fax 651 490 3824 Printed in USA www alnor com Part No 116 210 005 Rev 4 customerservice alnor com Thermo Anenometer Model 9850 Owner s Manual UL LISTED IN...

Страница 2: ...ct TSI Incorporated directly before returning your instrument See INSTRUCTIONS FOR RETURN Follow the procedure carefully as it will expedite processing Failure to follow the procedure may cause return of the unit unrepaired Send your instrument to the factory transportation prepaid To assure fast turn around time photocopy and fill out this form with as much detail as possible and attach it to the...

Страница 3: ...cated in specifications are warranted for a period of 90 days from the date of shipment to the customer b With respect to any repair services rendered Seller warrants that the parts repaired or replaced will be free from defects in workmanship and material under normal use for a period of 90 days from the date of shipment to the customer c Seller does not provide any warranty on finished goods man...

Страница 4: ...n the instrument is switched to the BATT position Do not attempt to adjust any of the calibration potentiometers unless access to a properly calibrated wind tunnel test facility is available Environmental conditions temperature pressure humidity air turbulence can produce different effects on the measured results for different instrument types These differences must be considered when comparisons ...

Страница 5: ...high reading scale The switch also has a BATT position where a portion of the battery voltage is substituted for the bridge output giving an indication of the voltage being provided by the battery GENERAL DESCRIPTION The Model 9850 Thermo Anemometer is a pocket sized battery operated analog readout portable instrument capable of measuring air velocities from 20 to 2000 FPM 0 1 to 10 m s in two ran...

Страница 6: ...ully extended the probe can be rotated 180 degrees to allow the meter to be easily read in air flows coming from various directions When in use the probe must be turned so that the air flow is in the same direction as the arrow on the top of the probe 3 Slide switch on the top of the instrument to the battery position Note the position of the needle on the instrument face It should be in the dark ...

Страница 7: ... remaining battery life If the needle rests in the narrow portion of the battery line plans for battery replacement should be made in the near future 4 Place anemometer in the air flow to be measured and slide switch on top of instrument to the HIGH position Read velocity on meter If velocity is below 250 FPM 1 2 m s move switch on top of instrument to LOW position for better resolution 5 Take and...

Страница 8: ...ons that is 25 degrees Celsius and 760 mm Hg barometric pressure Note A change in any one adjustment requires calibration of the zero adjustment high range span adjustment and low range span adjustment WARNING To maintain the instrument as intrinsically safe for use in hazardous locations use ONLY the following battery types Eveready 522 Duracell MN1604 Radio Shack 23 553 LIST OF MODELS AND PARTS ...

Страница 9: ...t is needed Zero Adjustment 1 Mechanically Turn instrument to OFF position and using a screw driver turn screw in front of instrument so the meter needle is lined up with the zero picket 2 Electrically Turn instrument to the LO position Cover probe sensor window to prevent any air flow and turn the ZERO adjustment screw on the left hand side of the instrument until meter needle lines up with the z...

Страница 10: ...MAINTENANCE The Model 9850 Thermo Anemometer is manufactured with solid state components Thus no maintenance is required other than periodic checking that the instrument and probe are clean and not damaged Cleaning Meter Window Clean with liquid eyeglass cleaner Do not use abrasives or solvents Case Use mild soap dishwashing detergent and water solution on a damp cloth to remove finger marks oils ...

Страница 11: ...MAINTENANCE The Model 9850 Thermo Anemometer is manufactured with solid state components Thus no maintenance is required other than periodic checking that the instrument and probe are clean and not damaged Cleaning Meter Window Clean with liquid eyeglass cleaner Do not use abrasives or solvents Case Use mild soap dishwashing detergent and water solution on a damp cloth to remove finger marks oils ...

Страница 12: ...t is needed Zero Adjustment 1 Mechanically Turn instrument to OFF position and using a screw driver turn screw in front of instrument so the meter needle is lined up with the zero picket 2 Electrically Turn instrument to the LO position Cover probe sensor window to prevent any air flow and turn the ZERO adjustment screw on the left hand side of the instrument until meter needle lines up with the z...

Страница 13: ...ons that is 25 degrees Celsius and 760 mm Hg barometric pressure Note A change in any one adjustment requires calibration of the zero adjustment high range span adjustment and low range span adjustment WARNING To maintain the instrument as intrinsically safe for use in hazardous locations use ONLY the following battery types Eveready 522 Duracell MN1604 Radio Shack 23 553 LIST OF MODELS AND PARTS ...

Страница 14: ... remaining battery life If the needle rests in the narrow portion of the battery line plans for battery replacement should be made in the near future 4 Place anemometer in the air flow to be measured and slide switch on top of instrument to the HIGH position Read velocity on meter If velocity is below 250 FPM 1 2 m s move switch on top of instrument to LOW position for better resolution 5 Take and...

Страница 15: ...ully extended the probe can be rotated 180 degrees to allow the meter to be easily read in air flows coming from various directions When in use the probe must be turned so that the air flow is in the same direction as the arrow on the top of the probe 3 Slide switch on the top of the instrument to the battery position Note the position of the needle on the instrument face It should be in the dark ...

Страница 16: ...high reading scale The switch also has a BATT position where a portion of the battery voltage is substituted for the bridge output giving an indication of the voltage being provided by the battery GENERAL DESCRIPTION The Model 9850 Thermo Anemometer is a pocket sized battery operated analog readout portable instrument capable of measuring air velocities from 20 to 2000 FPM 0 1 to 10 m s in two ran...

Страница 17: ...n the instrument is switched to the BATT position Do not attempt to adjust any of the calibration potentiometers unless access to a properly calibrated wind tunnel test facility is available Environmental conditions temperature pressure humidity air turbulence can produce different effects on the measured results for different instrument types These differences must be considered when comparisons ...

Страница 18: ...cated in specifications are warranted for a period of 90 days from the date of shipment to the customer b With respect to any repair services rendered Seller warrants that the parts repaired or replaced will be free from defects in workmanship and material under normal use for a period of 90 days from the date of shipment to the customer c Seller does not provide any warranty on finished goods man...

Страница 19: ...ct TSI Incorporated directly before returning your instrument See INSTRUCTIONS FOR RETURN Follow the procedure carefully as it will expedite processing Failure to follow the procedure may cause return of the unit unrepaired Send your instrument to the factory transportation prepaid To assure fast turn around time photocopy and fill out this form with as much detail as possible and attach it to the...

Страница 20: ...____________________________ _________________________________________ _________________________________________ TSI Incorporated Alnor Products 500 Cardigan Road Shoreview MN 55126 USA Toll Free 800 424 7427 Telephone 651 490 2811 September 2003 Fax 651 490 3824 Printed in USA www alnor com Part No 116 210 001 Rev 3 customerservice alnor com Thermo Anenometer Model 9850 Owner s Manual UL LISTED I...

Отзывы: