ALM-015 - ‘Akemie’s Taiko’
APPENDIX II: Calibration
Akemie’s Taiko is pre-calibrated at the factory to accurately track 1 volt per octave
on both VCOs. It should be accurate across approx 5 octaves.
Calibration is performed by carefully adjusting the trimmer on the back of the
module. To calibrate, apply 1V to v/oct input of oscillator you want to adjust. Now tune
the oscillator via front panel course and fine controls to C1. Next change the input
voltage to 3V and now adjust trimmer on reverse until you get C3.
You may want to use a bigger or different voltage interval. You can use a Beasts
Chalkboard as a stepped voltage source but you could also use a sequencer, offset
through quantiser, offset with a multi-meter etc.
.
!
10