The unit comes equipped with an adjustable thermostat
that is adjustable from 

175

to 

215˚

F.  Once the tempera-

ture inside the cabinet is reached the preset thermostat
setting, the thermostat will cycle on and off to maintain
the preset temperature.  The motor and fan will operate
continuously as long as the lighted “On-Off” switch is in
the “On” position.

Important: 

The internal cabinet temperature will

vary. Once the internal temperature has stabilized, the in-
ternal temperature will be at the preset setting (

175

to

215˚

F.) at the thermostat sensing disc. However, internal

temperatures will vary within the heated compartment.
From a cold start, two (

2

) hours is recommended to heat

the plates to the proper temperature. If warm plates are
inserted for heating, allow one and one half (

1 ½

) hours

for the subsequent cycles.

To maintain proper operation, the lids must be kept
closed except when inserting or removing plates. 

InstallatIon and start-up

1. 

Carefully remove all external packaging material and

carefully roll the unit off of the wooden skid. If damage is
discovered, retain all packing materials and immediately
file a concealed shipping damage claim with the trans-
portation company.

2.

Remove all tape and protective coatings from the unit.

3.

Important: 

Lift out the self leveling dispenser mech-

anisms and remove the corrugated packing materials
from the cabinet.

4.

Connect the unit to a proper electrical power source.

5. 

Load the unit with plates.  Since plates vary in height

and weight, the quantity will vary.

6. 

Close the lids and turn the

“On-Off” switch “On”. When
the switch is on, the switch
will light up.

sprIng adjustment 

dIspensIng mechanIsm

Important: 

SPRIng ADjuSTMEnT IS nOT COV-

ERED unDER WARRAnTy!

The dispensing springs are preset for Alluserv bases. If
spring adjustments are required:

1.

cautIon: 

Turn the unit off, open the lids and allow

for the internal temperature of the cabinet to cool down
to room temperature.  

cautIon: 

The bases will remain

hot for a long period of time. To remove them use heat
resistant gloves or a suction lifter. use insulated gloves to
remove plates.

2.

Open the lids, remove the lift out divider located be-

tween the dispensing mechanisms. 

3.

Lift the dispensing mechanism out of the dispenser by

grasping the handles located on each side of the dis-
penser.

Содержание CPH2

Страница 1: ...Plate Heater Service Manual Models CPH2 CPH3 888 892 2213 alluserv com...

Страница 2: ...allation Start up 4 Spring Adjustment 5 Cleaning 5 Troubleshooting 6 Service Access Information 7 Replacement Parts List 7 Replacement Parts Diagram CPH2 8 Replacement Parts Diagram CPH3 9 Replacement...

Страница 3: ...quest for inspection by the carrier within fteen 15 days of the delivery date The carrier will provide you with the proper form It is very important to keep all cartons pack ing materials and skids f...

Страница 4: ...the wooden skid If damage is discovered retain all packing materials and immediately le a concealed shipping damage claim with the trans portation company 2 Remove all tape and protective coatings fr...

Страница 5: ...unit from electrical power source units have an adjustable thermostat with a range of 175 to 215 F To adjust the thermostat once switches have been turned o and the unit has been unplugged remove the...

Страница 6: ...ring C unit does not operate and light does not come on 1 no electrical power to unit 2 Faulty power switch 3 Loose wiring 1 Make sure that unit is plugged in Check power at receptacle 2 Replace On O...

Страница 7: ...hat guards the fan blade and heating element This will provide access to the motor blower wheel and heating element replacement parts No Description Part Number CBH2 Qty CBH3 Qty 1 Lid Assembly End 50...

Страница 8: ...8 888 892 2213 alluserv com MoDel CPH2...

Страница 9: ...alluserv com 888 892 2213 9 MoDel CPH3...

Страница 10: ...10 888 892 2213 alluserv com DisPeNsiNg MeCHaNisM silo eleCtriCal sCHeMatiC...

Страница 11: ...ims can be made under this warranty agreement for direct special incidental or consequential damages including but not limited to spoilage of products for any reason or system failure Preventative mai...

Страница 12: ...alluserV llc 901 West 14th Street Suite 200 Washington MO 63090 888 892 2213 alluserv com Literature 2060 10 2010...

Отзывы: