RISK OF FLYING OBJECTS

- Do not direct compressed air stream at people or pets. The powerful compressed air stream can damage

exposed skin and easily propel loose dirt and other small objects at high-speed, resulting in serious injury. Always wear eye protection
that meets ANSI Z28.1 specifications. Use only OSHA approved air blowguns. Never leave a pressurized air compressor unattended.
Shut off air compressor and relieve pressure before performing maintenance or repairs. Do not move the air compressor while the air
tank is pressurized. Never attempt to move the air compressor by pulling on the air hose.

RISK OF FALLING

- Portable air compressors can fall from a table, workbench or roof causing damage to the compressor and could

result in serious injury or death to the operator. Always operate air compressor in a stable and secure position to prevent accidental
movement of the unit. Never operate air compressor on a roof or other elevated position. Use additional air hose to reach high loca-
tions.

RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR

- Oil can leak or spill and could result in fire or breathing hazard,

serious injury or death can result. Oil leaks will damage carpet, paint, or other surfaces in vehicles or trailers.

AIR TOOLS AND ACCESSORIES

- Do not exceed the pressure rating of any air tools, spray guns, air accessories, or inflatables. Excess

pressure can cause them to explode, resulting in serious injury. Follow the manufacturers recommended pressure settings for all air
tools and air accessories.

SPECIFICATIONS

• 3.5 Peak HP
• 11 Gallon Air Tank
• Oil Lubricated Direct Drive Pump
• Cast-iron Cylinder
• Maximum Pressure: 125 PSI
• Power: 115V, 60 Hz, 15 Amps
• Air Delivery: 4.7 SCFM output @ 40 PSI / 3.0 SCFM output @ 90 PSI
• Duty Cycle: 50%
• Thermal Overload Protection for Safety
• High Flow Regulator for Precision Air Flow Control
• Dual Pressure Gauges
• Weight: 84 lbs. (38 kg)

Duty Cycle:

Duty cycle refers to the percentage of time a compressor can safely run within a given amount of time expressed as a ratio. Oil lubricat-
ed compressors are typically rated at a 50% duty cycle, meaning that the compressor motor can run about 50% of the total time it is
being used to supply air to a tool. During the “on” time, the motor is running to pressurize the tank. During the “off” time, the motor is
stopped and the tools are running off on the pressurized air stored in the tank. If your air tools are draining pressure off of the tank too
quickly, the compressor motor must run more than 50% of the time the compressor is in use. This can lead to overheating and will sig-
nificantly shorten the life of the compressor. 

INSTALLATION AND LOCATION

The compressor must be used on a stable level surface. The air compressor must be used in a clean and well-ventilated area. The com-
pressor requires an unobstructed airflow and must be located a minimum of 20 inches from any walls or other obstructions.

6

WARNING

WARNING

WARNING

WARNING

Содержание Air-Plus 540010

Страница 1: ...1GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Страница 2: ...f any substance that might impair their vision dexterity or judgment Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury...

Страница 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Страница 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Страница 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Страница 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 11 Gallon A...

Страница 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Страница 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Страница 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Страница 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Страница 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Страница 12: ...move oil drain plug 4 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 5 Clean and replace oil drain plug 6 Refill crankcase with SAE 30 weight non detergent...

Страница 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Страница 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Страница 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Страница 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...