Alltion 29612 Скачать руководство пользователя страница 6

 

1.2 Adaptation of Product

 

 

The colposcope apply to clinical observation for the lesion of vagina, cervix, vulva, etc. 

Contraindication

 

      

1

Should not checking during menstrual period or vaginal bleeding 

2

Should not perform gynecological examination and cervical 

scraping smear before 24 hours of vaginal examination    to 
avoid the damage of epithelial cell. 

3

Should not have sex 3 hours before the vaginal examination. 

4

Should not take bath in tub ,vaginal douche and use suppository 

1 day before the vaginal examination 

1.3 Product Formation 

 

The colposcope of AC-1000 series are composed with optical system (include objective, 

variable-power lens, eyepiece, illuminating system, stand and electrical system. You can 
choice various corresponding mountings for different requirements. 

2  Security 

2.1 Intended Use 

The colposcopy Examination can help doctor to discover and ensure the information 

(location, detail, condition, range and extent) of cervical erosion, cervical polyp, cervical 
intraepithelial neoplasia (CIN), cervical cancer, colpitis, cervical intraepithelial neoplasia, 
subclinical vulvar papilloma lesion.   

The colposcope is not only worth diagnosing cervical precancerous lesions and 

distinguishing tumor or inflammation, but also have special applied worth in treatment, 
especially the lesion of cervical intraepithelial neoplasia (CIN).Because the colposcope can 
see the location and range of epithelia changement, you can use the colposcope take more 
information about the examination of urethra and vulva in the same way. Its main function

   

● Ensure cervical precancerous lesions, it is in favor of wipe out earlier, prevent it grow 

into cancer

   

● Choice abnormal lesion, Locating biopsy, Increase the positive rate of biopsy

   

 

 

Содержание 29612

Страница 1: ...r s Manual Please read the instruction carefully before using it All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and competent authority of the...

Страница 2: ...or use WEEE disposal Handle With Care Keep in a cool dry place Upward For indoor use Equipotentiality Medical device Product code Alltion Guangxi Instrument Co Ltd Alltion Building NO 10 3rd Road Wuzh...

Страница 3: ...uction carefully before operating It shall change some components to improve the quality and performance of instrument Therefore it may have some different with the instruction Please know that the st...

Страница 4: ...1 AC 1110 Features 10 3 5 2 AC 1310 Features 10 3 5 3 AC 1320 Features 11 4 Installation of Colposcope 12 4 1 Contents of Box 12 4 2 Removing the Colposcope from the Box 12 4 3 Setting up the Colposco...

Страница 5: ...teaching research Classified by prevent electric shock type II type Colposcope model labeled graph as follows AC X X X X the code for built in CCD camera expression by a number the code for the eyepi...

Страница 6: ...ferent requirements 2 Security 2 1 Intended Use The colposcopy Examination can help doctor to discover and ensure the information location detail condition range and extent of cervical erosion cervica...

Страница 7: ...etric Pressure Range 700 hPa 1060 hPa Power Supply DC12 3A Adapter Input AC100 240V 50 60Hz Output DC12V 3A 2 3 Feature of Security a Classified by prevent electric shock type II type b Classified by...

Страница 8: ...you move of a sure color balance Now easier to move with our new roller base Plus once in position the platform remains stable 360 Motion On off Switch and Power Indicator Light Roller Base Rheostat K...

Страница 9: ...Power Plug 5 5 2 1mm LED Bulb Cover Green Filter Knob Rheostat Knob Head Inclination Adjusting Knob Diopter Knobs Fine Height Adjustment Handle Fine Focus Handle Gross Height Adjustment and Locking K...

Страница 10: ...move with our new Roller base Plus once in position the platform remains stable LED Bulb Cover Diopter Knobs Three step Magnification Knobs Head Inclination Adjusting Knob Rheostat Knob Fine Focus Han...

Страница 11: ...ob These circles give you the millimeter size at the tissue site according to the magnification you re using Diopter Knobs Fine Height Adjustment handle Fine Focus Handle Gross Height Adjustment and L...

Страница 12: ...ier to move with our new Roller base Plus once in position the platform remains stable LED Bulb Cover Diopter Knobs 45 Inclined Binocular Three step Magnification Knob Rheostat Knob Fine Focus Handle...

Страница 13: ...rcles give you the millimeter size at the tissue site according to the magnification you re using 45 Inclined Binocular LED Bulb Cover Rheostat Knob Head Inclination Adjusting Knob Diopter Knobs Fine...

Страница 14: ...as to be tightened or adjusted and it gives you fluid 360 motion for gross focus A space saving small footprint Length is 360mm Width is 310mm Clutter reducing internal power cable Working height 838m...

Страница 15: ...r true stereoscopic view Optical measuring circles for precise measurements Optic angle is 45 Focal length 300mm Magnification 15X 7 5X 3 75X Field of View 9 5mm 19mm 38mm dia Depth of Field 5mm 8mm 3...

Страница 16: ...material Grasp the colposcope at the center post A cutout in the foam for your hands is provided and lift the colposcope straight out of the protective material Note When removing the instrument out...

Страница 17: ...stable temperatures to extend the life of the components and ensure longevity of the instrument B Please cover the colposcope with the plastic dust cover that is included with this instrument This wil...

Страница 18: ...djustment of the Diopter Knobs Focusing the Colposcope A Set the Diopter Knobs at zero B Turn the Colposcope on place your eyes against the eyepieces and focus the Colposcope on a fixed object until t...

Страница 19: ...d of the adjustments on the Diopters for both your left and right eyes Since most offices have multiple people using the Colposcope the eyepieces will be different when someone else wants to use it By...

Страница 20: ...t and Locking Knob to loosen it and move the inner post up or down Tighten the knob to lock the inner post in place B In a sitting position place your feet on the rubber pad part of the base Place you...

Страница 21: ...Head Left Move Head right Twist the adjustment handle to move the head up or down Push the Fine Height Adjustment Handle forward and to the left counterclockwise Pull the Fine Height Adjustment Handl...

Страница 22: ...be examined Rotate your left hand on the Fine Focus Handle which will finely move the optics towards or away from the object that you wish to view Also rotate your right hand which is on the Fine Heig...

Страница 23: ...Locking Knob to move the post to a comfortable position B Tighten the Gross Height Adjustment and Locking Knob C Place your foot between the wheels at the front end of the base D With your hand on the...

Страница 24: ...IEC 61000 3 3 Complies Guidance and Manufacturer s Declaration electromagnetic Immunity for all Equipment and Systems Guidance and manufacturer s declaration electromagnetic immunity The AC 1000 is i...

Страница 25: ...ufacturer s Declaration electromagnetic Immunity for Equipment and System that are not Life supporting Guidance and manufacturer s declaration electromagnetic immunity The AC 1000 is intended for use...

Страница 26: ...netic is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile...

Страница 27: ...the communications equipment Rated maximum output of transmitter W Separation distance according to frequency of transmitterm 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz P E d 5 3 1 800 MHz to 2...

Страница 28: ...he diode gear of the multimeter to touch the positive and negative of the LED supply line LED light shiny circuit board damage The LED not light the circuit board and the LED are damaged Contact the A...

Страница 29: ...n the lens can be cleaned with blown ballon or whisk pen Should not use corrosive or scrub cleanser to clean the lens The sterilize for the Colposcope All disinfectant cover can sterilize by pressure...

Отзывы: