4AC 14* ASA1  SERIES

R-410a  CONDENSING UNITS

INSTALLATION GUIDE

ATTENTION, INSTALLER!

After installing the system, show the user how to turn off 

electricity to the unit.  Point out control and switch locations 

for turning off electricity.  Make sure the user understands 

the importance of following all safety precautions, including 

what could happen if they don’t.

Keep the following documents in a safe, accessible location.  

Tell the user where these documents are located:

•  Installer’s Information Manual

•  Parts List

•  Warranty Information

While these instructions have been written as accurately 

and thoroughly as possible, they may not cover every 

system variation or contingency.  Questions of interpretation 

may arise.  For more information, solutions to particular 

problems or clarification, contact your local distributor or the 

manufacturer.

ATTENTION, USER!

Your equipment installer should give you the important 

documents listed above.  You should become familiar 

with these instructions, as it will be helpful in avoiding any 

needless service costs or operational problems.  Keep 

these instructions as long as you keep your equipment for 

future reference.  If any of the documents are missing or 

illegible, contact your installer or equipment manufacturer 

for replacement.

Throughout this manual, when we use the word “you” we 

refer to the qualified service technician who is responsible 

for application, installation, and service of your equipment.

While these instructions are addressed primarily to the 

installer, useful maintenance information is included.  Have 

your installer acquaint you with the operating maintenance 

requirements.

 

    

WARNING:

   Individuals who install this equipment, must have the training and experience necessary 

to install comfort air conditioning appliances.  Before performing any work on this equipment, the power supply 

must be turned off at the household service box.  Improper installation could void the warranty;  create a hazard, 

resulting in the possibility of damage, injury or death.

   

  

R

-410

A

816080 B

Содержание 4AC13018ASA1

Страница 1: ...documents listed above You should become familiar with these instructions as it will be helpful in avoiding any needless service costs or operational problems Keep these instructions as long as you k...

Страница 2: ...ou to potential hazards we use the signal words WARNING and CAUTION throughout this manual WARNING alerts you to situations that could cause or result in serious injury or death CAUTION alerts you to...

Страница 3: ...n Agency EPA has issued various regulations regarding the introduction and disposal of refrigerants in this unit Failure to follow these regulations may harm the environment and can lead to the imposi...

Страница 4: ...d be give to water drainage away from the outdoor unit Drain holes in the base pan must be kept clear SECTION 4 REFRIGERANT PIPING CONNECTIONS Undersizedlinesetswillincreasetherefrigerantpressure drop...

Страница 5: ...ighten This opens the valve completely The gauge port is open accessible at all times CAUTION Extreme care should be used when brazing joints Keep torch away from condenser cabinet aluminum coil and p...

Страница 6: ...hich have Thermostatic Expansion Valve TXV as the expansion device For proper sub cooling readings a standard high side gauge is required for pressure readings 1 Measure the outdoor air temperature T1...

Страница 7: ...ing unit for unusual noise and undue vibration 5 Allow the system to operate until it is balanced or stabilized approximately 30 minutes before making further checks 6 Remove manifold gauge hoses and...

Страница 8: ...t Installer s Information Manual Page 8 SUB COOLING CHART FOR UNITS WITH THERMOSTATIC EXPANSION VALVES 18 16 14 12 10 8 6 4 60 65 70 75 80 85 90 95 100 105 110 115 Remove Refrigerant Add Refrigerant S...

Страница 9: ...ect voltage Defective overload protector Refrigerant undercharge At compressor terminals voltage must be 10 of nameplate marking when unit is operating Replace check for correct voltage Add refrigeran...

Страница 10: ...Installer s Information Manual Page 10...

Страница 11: ...Installer s Information Manual Page 11 NOTES...

Страница 12: ...Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specification without notice Installer s Information Manual Rev 8 2015...

Отзывы: