The following lists the ordering number and description for accessory components 

available to maintain the ScanX to meet your professional needs. Contact your 

authorized dealer for information.

ACCESSORIES

One re-usable Release Liner is included in each box of ScanX Cleaning Sheets

.

Description

Quantity

Part No.

ScanX Cleaning Sheets* for B7150

Box of 12

B3010

Box of 25

B3020

ScanX Cleaning Sheets* for B7350

Box of 12

B2010

Box of 25

B2020

ScanX Dust Cover Kit

1

74050

Intraoral Plate Guides

Size 0

1

73566-0

Size 1

1

73566-1

Size 2

1

73566-2

Size 3

1

73566-3

Intraoral Phosphor Storage Plates

Size 0

2 per package

73445-0

Size 1

2 per package

73445-1

Size 2

4 per package

73445-2

Size 3

2 per package

73445-3

Size 4

1 per package

73445-4

Intraoral Barrier Envelopes

Size 0

100 per package

73248-0

Size 1

100 per package

73248-1

Size 2

300 per package

73248-2

Size 3

100 per package

73248-3

Size 4

50 per package

73248-4

Medical Phosphor Storage Plates

8 x 10 inches

1 per package

73578-8M

10 x 12 inches

1 per package

73578-10

Plate Protectors

8 x 10 inches

1 per package

B2160-8M

10 x 12 inches

1 per package

B2160-10

Cassettes

8 x 10 inches

1 per package

74190-8

10 x 12 inches

1 per package

74190-10

Plate Transfer Box

1

74570

Power Supply

1

B7095

Line Cord

1

73096

6-Ft Computer Connector Cable, USB

1

B3554

15-Ft Computer Connector Cable, USB

1

B5026

PSP Wipes

Box of 25

B8910

Содержание ScanX Duo DVM

Страница 1: ...Instruction Manual Part Numbers B7150 and B7350 ScanX 12 DVM P N B7350 ScanX DVM P N B7150...

Страница 2: ...Important Information 7 Purpose of this Manual 8 System Description 8 Unpacking and Inspection 9 If You Need Assistance 9 Computer System Requirements 10 Controls and Indicators 11 Technical Data 12 A...

Страница 3: ...to other applications If your ScanX cannot be repaired in the field and turns out to be defective due to faulty materials and or workmanship within the warranty period ALLPRO Imaging will arrange to...

Страница 4: ...could cause fire or explosion Alerts users to important Operating and Maintenance instructions Read carefully to avoid any problems Warns users that uninsulated voltage within the unit may be of suff...

Страница 5: ...cessible by removing hardware with tools It should be opened and serviced only by an authorized dealer service technician Failure to heed this warning may result in equipment damage or personal injury...

Страница 6: ...ains a laser and is a Class 1 Class 1 IEC Laser Product Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure The las...

Страница 7: ...fully dry again Air Techniques regard themselves as being responsible for the equipment with regard to safety reliability and proper functioning only if assembly resetting changes or modifications an...

Страница 8: ...acturer is not to be held liable for any damage caused as a result of incorrect usage The operator bears all risks This manual provides the information necessary for the setup operation and routine ca...

Страница 9: ...noted notify your authorized dealer immediately so corrective action can be taken IF YOU NEED ASSISTANCE ALLPRO Imaging ScanX systems are designed and manufactured to high standards They are easy to...

Страница 10: ...with Service Pack 2 or later for an Intel 64 bit extended x64 processor Microsoft Windows Vista Business Enterprise or Ultimate with Service Pack 1 or later for an Intel 32 bit or an Intel 64 bit ext...

Страница 11: ...inates steady blue to indicate that the Erase function is ON and PSPs will be erased after scanning Flashes blue to indicate that the Erase function is OFF and PSPs will not be erased after scanning 4...

Страница 12: ...to 18 lp mm 2 5 to 18 lp mm Compliance Data Laser Class Class I Laser Product 21 CFR 1040 10 Class 1 Laser Product IEC 60825 1 Laser Product Report Accession Number 0212282 00 Installation Category I...

Страница 13: ...ant computer hardware and software SITE SELECTION Abbreviations used in this manual are summarized below A ampere s AC alternating current CD ROM compact disk read only memory CFR Code of Federal Regu...

Страница 14: ...ELECTION guidelines 2 Set up the computer according to the manufacturer s recommendations Make sure that the computer meets all requirements listed on page 10 3 Verify that an authorized Imaging Softw...

Страница 15: ...e Mains disconnect device Power Supply Line Cord Press HERE to turn ON or OFF Green LED Indicator ALLPRO IMAGING READY ERASER FLASHING OFF ALLPRO IMAGING READY ERASER FLASHING OFF Blue LED Indicator E...

Страница 16: ...sunlight and ultraviolet rays Pick up the PSPs using two fingers around the edges to avoid unnecessary contact with the plates CAUTION Always use a Barrier Envelope for each Intraoral plate Exercise...

Страница 17: ...MPORTANT Wipe the phosphor side of the plate only making sure not to scratch the plates Cleaning Phosphor Storage Plates For the best images PSPs should be handled carefully and kept clean Use the fol...

Страница 18: ...f the adhesive strip and seal the envelope See Figures 4a 4c below The Barrier Envelope must be used only once and disposed of properly in accordance with local code 2 Barrier Envelope Handling Always...

Страница 19: ...ies When all necessay plates in the X ray session have been exposed prepare each plate by performing the procedure below Preparing the Exposed Plate for Scanner Processing 1 Disinfect the Barrier Enve...

Страница 20: ...Scanner is transporting the PSP Configure the Intraoral Plate Guides If the desired Plate Guides are not in place install these Guides at this time Do not operate the scanner without a full complemen...

Страница 21: ...ch scanned image using the user supplied authorized Imaging Software ALLPRO IMAGING READY ERASER FLASHING OFF ALLPRO IMAGING READY ERASER FLASHING OFF READY Switch BLUE LED Indicator ERASER Switch GRE...

Страница 22: ...s instructions for PSPs 3 Bring the cassette containing the exposed extraoral PSP to the ScanX The PSP is now ready to be scanned Activate Scanner Activate the ScanX by performing the following proced...

Страница 23: ...always be erased prior to expo sure to X rays for new images Scanning Plates without Erasing The ScanX can be operated with the in line eraser feature turned off When the eraser mode is disabled the...

Страница 24: ...ek using a new ScanX Cleaning Sheet each time Sample sheets are included with the ScanX and additional sheets can be purchased from your dealer Refer to ACCESSORIES page 27 Disinfecting the ScanX No d...

Страница 25: ...tes PSPs PSP s are subject to wear on the black side during normal handling and use They can appear scratched while the sensitive side blue or white remains relatively smooth This scratched look on th...

Страница 26: ...puter System require ments Page 10 Make sure that the READY switch is set to ON and the green indicator light is illuminated Reconnect the cable Check for tightness Replace if necessary Verify that th...

Страница 27: ...SP has been stored too long in barrier envelope or cassette Partial erasure of the image due to exposure to light during handling of the PSP Make sure ScanX is operating with eraser turned on blue LED...

Страница 28: ...tes Size 0 2 per package 73445 0 Size 1 2 per package 73445 1 Size 2 4 per package 73445 2 Size 3 2 per package 73445 3 Size 4 1 per package 73445 4 Intraoral Barrier Envelopes Size 0 100 per package...

Страница 29: ...e images to personal preferences with our simple Set Up 1 2 3 tool Exposure Our Stop Light Exposure System is a unique indicator to ensure optimum data capture It helps you acquire great images by mon...

Страница 30: ...30 NOTES...

Страница 31: ...31 NOTES...

Страница 32: ...markets Thousands of ALLPRO Imaging products have been sold globally installed and serviced through our network of authorized dealers 100 Plus 2010 PolarisJ ScanX 12 ScanX 12 DVM ScanX Discover ScanX...

Отзывы: