To ensure your new pond filter is set up and running correctly, and to prevent any 

accidental damage or injury, please read and follow the below instructions 

carefully before using your product.

 

SAFETY

IMPORTANT!

 

Disconnect the mains electricity supply before attempting any 

installation / maintenance of any kind. Do not attempt to modify this unit in 
any way and only use the recommended parts for replacement.

·    

 

The PR pressurised pond filter should never be run dry as this will cause the 

unit to overheat and cause permanent damage.

·     

All connections must be earthed.

·     

The power cord of this appliance cannot be replaced; if the cord is 

damaged, the appliance should be discarded. Never cut the cord.

·      

Do not connect to any voltage other than that stated.

·      

Do not place in liquids other than water.

·      

Do not use with water above 90°F or 30°C.

·      

Do not carry or pull the unit by its electrical cable.

·      

Do not use this unit if it has a damaged cord, if it is malfunctioning or it is 

dropped or damaged in any manner

·      

Do not attempt to modify this unit in any way and only use attachments and 

the recommended parts for replacement recommended by the 
manufacturer.

·     

 Before installing, maintaining or handling your equipment, or before placing 

your hands in your pond, ensure that the unit is disconnected from the 
electricity supply.

·      

Always disconnect any electrical devices when not in use.

·     

 Carefully examine your pond system after installation. Do not connect the 

unit to the mains if there is water on any parts not intended to be wet. 

 

·     

Do not look directly at the UV light when it is operational.

 

·     

Before operating your unit observe that  water is flowing through it - the UV 

requires constant flow to avoid overheating.

Содержание PF-12000

Страница 1: ...PRESSURISED POND FILTER PF 8000 12000 20000 LARGE FILTER VOLUME PRESSURISED CLOSED SYSTEM BUILT IN STERILISER BIO MECHANICAL FILTRATION SIMPLE USER FRIENDLY OPERATION...

Страница 2: ...Do not place in liquids other than water Do not use with water above 90 F or 30 C Do not carry or pull the unit by its electrical cable Do not use this unit if it has a damaged cord if it is malfunct...

Страница 3: ...tered area ensuring all water has been drained from the lter Do not bury the cord for this unit Ensure it does not cause a trip hazard or it at risk from damage from lawn mowers strimmers or other gar...

Страница 4: ...anently installing to the mains supply Please Ensure The power supply must be earthed and fused at 3amps Regularly inspect the cable for damage and deterioration Consult a quali ed electrician if in d...

Страница 5: ...etimes you may notice the spindle stops rotating this is okay as long as the water runs through the unit Make sure the O rings are placed smooth side up to the hosetail see image on the right for refe...

Страница 6: ...validate your warranty We recommend that a regular cleaning and maintenance schedule is followed to ensure responsible shkeeping Depending on water volume and stocking levels regular cleaning of the l...

Страница 7: ...h you have How often you feed your sh and seasonal light levels will also a ect how quickly your pond water gets dirty and will need to be taken into consideration when planning how often to clean you...

Страница 8: ...order to remove the lter sponges untwist the plate holder in an anti clockwise direction Rinse them in pond water to prevent damaging the bene cial bacteria which help maintain a healthy pond General...

Страница 9: ...sembling your unit you must replace all O rings as per the parts diagram as otherwise this can cause the unit to leak which will cause permanent damage to the UV operation Remove the quartz sleeve fro...

Страница 10: ...by this stage The PF 8000 PF 12000 use an 11w two pin PLS UV bulb The PF 20000 uses an 18w two pin PLL UV bulb NEVER look directly at the UV light When replacing your UV bulb use this time to clean yo...

Страница 11: ...2 3 4 5 6 7 8 QUARTZ SLEEVE O RING 1 O RING BALLAST COVER UV BALLAST UV CLARIFIER 1 2 3 4 5 QUARTZ SLEEVE QUARTZ SLEEVE O RING 2 6 7 CLEANING INDICATOR 8 5 HOSETAIL 9 10 FILTER LID 10 9 10 11 12 13 14...

Страница 12: ...ET OUTLETHOSEADAPTER DIMENSIONS LxWxH mm UV POWER WATTAGE SUITABLE FOR DECORATIVE PONDS UP TO 5m Plug not included SUITABLE FOR PONDS WITH SMALL MIX OF FISH UP TO CABLE LENGTH 9000 L H MAX FLOW RATE M...

Страница 13: ...owed place and do not look directly at the bulb we recommend covering the bulb with kitchen roll or similar You should still be able to see the glow of the bulb through this 4 If the above does not so...

Страница 14: ...uth facing gardens inevitably get more sunlight and can cause ponds to be greener in the summer if exposed all day Try and shade your pond water surface plants are a great way to do this My Pond Water...

Страница 15: ...t all O rings are in place and well lubricated If none of the above resolves your issue or you require spare parts for your lter please contact the supplier of your unit My lter is leaking 1 Check tha...

Страница 16: ...lbs are not covered by your warranty and a charge may be required for replacements of these This warranty does not apply to any unit that has been subjected to misuse accidental damage negligence tamp...

Страница 17: ......

Страница 18: ...www allpondsolutions co uk All Pet Solutions Limited Trading as All Pond Solutions Unit 203 Riverside Way Uxbridge Middlesex England UB8 2YF...

Отзывы: