Страница 2: ...to any voltage other than that stated This lter is suitable for indoor household aquariums only do not use in exterior locations swimming pools ponds bathrooms etc Do not place in liquids other than...

Страница 3: ...BIO BALLS BASKET IMPELLER BEARING 1 2 3 4 5 6 FILTER CASING 10 11 12 O RING BASE SUCTION CUPS 10 11 12 SCREW SCREW NUT QUARTZ TUBE 13 14 15 MOTOR 7 UV BULB 8 5 LAMP TUBE PROTECTIVE SLEEVE 9 UV BULB 8...

Страница 4: ...s unit from for further advice If the plug does get wet DON T unplug the cord First disconnect the circuit breaker or fuse that supplies power to the appliance Next unplug and inspect for water presen...

Страница 5: ...unctions correctly regular maintenance is essential Failure to do so may result in damage to your unit and may invalidate your warranty We recommend that a regular cleaning and maintenance schedule is...

Страница 6: ...planning how often to clean your unit UV OPERATION It is vital that O rings are regularly inspected and replaced as the rubber watertight seal will perish over time which may cause leaks Before replac...

Страница 7: ...and screw replace the 700IF body IMPORTANT Check regularly that your UV light is operational by looking at the UV light indicator located on the front of the 700IF This will light up blue if the UV l...

Страница 8: ...MPORTANT Never use tap water or soap or detergents when cleaning your unit or rinsing media Make sure no debris is trapped inside Filter Foam Media Remove the top cover from the unit by squeezing both...

Страница 9: ...d still and has not been knocked out of its connection point Attach the Suction Cups to the Base Plate Make sure you twist them by 90 degrees as per photo below or they will keep falling out attach th...

Страница 10: ...re the impeller is free of any type of blockage and can rotate freely inside the motor head The Light on My 700IF Isn t Working If the UV indicator at the front of the lter is not lighting up follow t...

Страница 11: ...udy water in a newly lled tank is a high level of dissolved constituents such as phosphates silicates or heavy metals If you test the water you ll likely nd that the pH is high alkaline In these cases...

Страница 12: ...arium Follow the instructions in the maintenance section If you have not yet done so you may also need to carry out more regular water changes in your tank No Water Is Coming Out Of My Filter Causes T...

Страница 13: ...ong with a valid proof of purchase and postage paid We reserve the right to replace or repair the unit at our discretion Please be aware that perishable parts that are subject to normal wear and tear...

Страница 14: ...hen completing a replacement or repair Spare parts are available at our o cial website or from your local supplier Before returning your unit under warranty terms check that all setup and maintenance...

Страница 15: ......

Страница 16: ...www allpondsolutions co uk All Pet Solutions Limited Trading as All Pond Solutions Unit 203 Riverside Way Uxbridge Middlesex England UB8 2YF...

Отзывы: