BWS-136 User Manual_amend.doc

 

- 27 -

 

 

Flow Control: None 

 Interface: 

RS-232 

Now you can use serial terminal software to send the ASCII 

command to BWS-136.   

 

In Serial Console Mode, all the network functions will be 

disabled 

 

Once the configuration is completed, remember to switch SW1 

back to Normal operation mode and reboot the module by Reset 

Command or push reset button. 

 

Telnet Console Mode 

BWS-136 uses Port number 

5001

 as telnet console port.   

Remember to turn on the LOCALECHO before opening the telnet 

console port.    You must login first before sending command to 

BWS-136.    If password is enabled, you need to use the password 

to log in.    The password is encrypted using Tiny Encryption 

Algorithm (TEA) and the keys are sixteen bytes with low case 

character from “a” to “p”.    The login command format is as 

follow: 

$LOG[16 bytes of TEA Encrypted Password] 

or  

$LOG 

if there are no password settings 

 

BWS-136 User Manual_amend.doc

 

- 28 -

 

Forgot Password 

If you forgot the Password, you can switch SW1 to Factory Default 

setting mode and use default IP Address 

192.168.16.10 

and enter the 

Web console pages.    Once the configuration is completed, 

remember to switch SW1 back to Normal operation mode and 

reboot the module by Reset Command or push reset button. 

Password is not required for serial console mode.    Therefore you 

can also use serial console to reset the password. 

 

Command Syntax 

The command syntax is   

[Delimiter][Command][Carriage Return/

CR

][Line Feed/

LF

Delimiter (one byte)

: The command begins with a delimiter of 

dollar sign $ and if BWS-136 receives the correct command it will 

response with an echo which begins with the delimiter of a 

percentage sign %.   

Command

: The command are ASCII string which contains three 

elements: {

R

ead/

W

rite}{Function}{Parameter} as described as 

follow: 

Содержание Network Device BWS-136

Страница 1: ...ut 7 Connecting Power 7 Connecting Ethernet Port 8 Connecting Serial Port 8 Switch SW1 Settings 8 LED Status 10 Serial Port Pin Assignments 11 Factory Default Settings 13 Configure BWS 136 14 Install...

Страница 2: ...g capability BWS 136 converts the serial data to standard TCP IP protocol therefore the serial device can be accessed everywhere via Internet or Ethernet In addition BWS 136 provides an embedded Web s...

Страница 3: ...SD Digital Input Output General Purpose DIO x8 DIO0 to DIO5 Programmable Digital I O TTL DIO6 to DIO7 Programmable Digital I O CMOS BWS 136 User Manual_amend doc 6 Software Protocol TCP IP HTTP ICMP D...

Страница 4: ...to the Ethernet port of BWS 136 The Link Activity light will keep solid yellow color if Ethernet cable is corrected to the network and this light will keep flashing if there are data transmitted Conn...

Страница 5: ...s The LED provides the BWS 136 operation information The LED status is described as follow Power LED Power LED keeps ON if power 9VDC to 40VDC is correctly input to BWS 136 Ready LED Ready LED keeps O...

Страница 6: ...Data 4 DTR RxD Data 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 BWS 136 User Manual_amend doc 12 Digital I O Digital I O uses DB9 connector and the pin assignments are described as follow Pin 1 DIO4 Pin 2 DIO3...

Страница 7: ...Data Format N 8 1 Parity Data bits Stop bits Flow Control None Interface RS 232 BWS 136 User Manual_amend doc 14 Configure BWS 136 Aport 211 provides four ways to configure the settings They are 1 Ja...

Страница 8: ...address of the module you can click Search by IP item and specify the IP address to find the BWS 136 User Manual_amend doc 16 BWS 136 The default IP address of BWS 136 is 192 168 16 10 Click on the r...

Страница 9: ...IP Address TCP port and operation mode as follow OpMode TCP operation mode setting TCP Port TCP Port number of BWS 136 Destination IP The IP address of remote host which BWS 136 will actively connect...

Страница 10: ...on Pages in the next entry BWS 136 User Manual_amend doc 20 Save Configuration After the all the settings are configured click to the Save to Module button to save the settings to the module The new s...

Страница 11: ...BWS 136 by using the Import button BWS 136 User Manual_amend doc 22 4 Web Configuration Overview BWS 136 can also be configured by Web Browser The build in Web server and Web configuration pages makes...

Страница 12: ...nd doc 24 Customize Your Web Page After you complete your web page design you can use the Manager Utility manager jar to upload the Web page to bws 136 Web server The web files need to be converted to...

Страница 13: ...er can use serial terminal or Telnet command to configure BWS 136 when Web browser and Java utility are available In addition these functions provide user the most convenient way to develop their own...

Страница 14: ...nd format is as follow LOG 16 bytes of TEA Encrypted Password or LOG if there are no password settings BWS 136 User Manual_amend doc 28 Forgot Password If you forgot the Password you can switch SW1 to...

Страница 15: ...136 User Manual_amend doc 30 RS 422 RS 485 G S LI IP Address e g SLI192 168 2 127 G S LN Netmask e g SLN255 0 0 0 G S LG Gateway e g SLG192 168 2 254 G S LC IP Mode 0 Static IP 1 DCHP G LM MAC Defaul...

Страница 16: ...etting as Default setting System S EI Exit console DIO S DM Set Digital I O mode I Input O Output H pull high L pull low BWS 136 User Manual_amend doc 32 e g SDMI 0 4 5 set DIO0 DIO4 DIO5 as input SDM...

Страница 17: ...dham of the Cambridge Computer Laboratory Placed in the Public Domain by David Wheeler and Roger Needham ANSI C VERSION New Variant Notes TEA is a Feistel cipher with XOR and addition as the non linea...

Страница 18: ...igned long const v unsigned long const w const unsigned long const k register unsigned long y v 0 z v 1 sum 0xC6EF3720 delta 0x9E3779B9 n 32 sum delta 5 in general sum delta n while n 0 z y 4 y 5 y su...

Отзывы: