Deploying the SG-9500
6-16
SG-9500 Hardware Guide
Configuration
Active redundancy can be configured on the Service Gateway either via the
NetXplorer GUI or via AOS CLI.
Via NetXplorer GUI
To configure Active Redundancy:
1.
Log into the NetXplorer
2.
Select the Service Gateway you wish to configure in the Navigation Pane.
3.
Right-click the Service Gateway and select
Configuration
from the drop
down menu.
OR
Click the
Configuration
button in the Toolbar.
4.
Open the
NIC
tab and in the
Action on Failure
field, set the traffic ports as
indicated in the tables above to
fail paired port
.
5.
Set all cloned port indicated in the tables above to
No Action
in the
Action
on Failure
field.
6.
Open the
Networking
tab and set the
Redundancy Mode
to
Active
.
7.
Confirm that the
Enable Bypass Unit
checkbox is not selected.
8.
Click
Save
. The system will reboot.
After rebooting, you can view the changes from the Configuration tab.
For more information concerning Service Gateway configuration via NetXplorer,
see the
NetXplorer Operation Guide
.
Via AOS CLI
To configure Active Redundancy:
Log into the Service Gateway and enter the following commands:
To disable the bypass unit:
go config network -bypass_unit disable
To set redundancy mode:
go config network -redund_mode active