ALL-MC115VDSL2 Mini Modem Master/Slave Manual
7
2.3 General Rules
Before making any connections to the bridge, please note the following rules:
•
Ethernet Port (RJ-45)
All network connections to the bridge Ethernet port must be made using Category 5 UTP or above for
100Mbps, Category 3, 4 UTP for 10Mbps.
No more than 100 meters of cabling may be use between the MUX or HUB and an end node.
•
VDSL2 Port (RJ-11)
All network connections to the RJ-11port must use 24~26 gauge with twisted pair
phone wiring.
We do not recommend the use of the telephone line 28 gauge or above.
2.4 Connecting the Bridge
The bridge has two Ethernet ports which support connection to Ethernet operation. The devices attached to these
ports must support auto-negotiation or 10Base-T or 100Base-TX unless they will always operate at half duplex. Use
any of the Ethernet ports to connect to devices such as Monitor system, Server, Switch, bridge or router.
Notes:
1. The RJ11 Line port is used to connect to telephone that is connected to VDSL CO and CPE bridge (Point-to-point
solution).
2. Slave device(CPE) must connect Master device(CO) through the telephone wire. Slave cannot connect to Slave,
and Master cannot connect to Master. Please confirm the DIP switch status before the link is established.