16 ALLMAND.COM
Checking and Draining Pre-Filter for Condensate
1. When red float (
A
) under element (
B
) in Pre- filter
is raised up to upper level, drain water.
2. Turn fuel selector valve (
C
) to OFF position.
3. Loosen the drain valve (
D
) and drain out
condensed water inside.
NOTE:
Make sure to tighten the drain valve
securely, after draining the condensate.
4. Drain the condensate in container and dispose of
condensate according to the local, state and/or
federal regulations.
Checklist Before Starting Engine
Review the unit’s assembly to ensure you have
performed all of the following.
1. Be sure to read
Operator Safety
and
Operation
before operating the comprressor.
2. Make sure compressor is in place and secure.
3. Check that oil has been added to proper level.
4. Check wiring of each part for any loose
connections, damage to insulating sheathed
portion, disconnection, and short circuit.
5. Check piping of each part for any loose
connections, tears, and leaks.
6. Check each hose for tear and leaks.
7. Clean debris from interior of unit. Periodically
check the inside of the unit for debris. Any
flammables such as chips of wood, dead leaves,
and waste paper, especially near the muffler and
exhaust pipe, should be removed.
WARNING
Operation with compressed
air supply port opened is prohibited.
• Do not operate machine with service valves and
relief valve open unless air hoses and/or pipes are
connected. Unregulated, high-pressurized air could
result in serious injury.
• When the machine has to be unavoidably
temporarily operated with its port open, be sure to
mount a silencer to reduce noise and wear personal
protective equipment (PPE) such as earplugs to
prevent hearing damage.
WARNING
• Keep the door closed and locked while running the
unit.
• When the door has to be opened, be careful not to
touch portions that are rotating or very hot. Careless
contact could result in serious injury.
• Pull the handle forward to open the door.
• Be sure to close the door tightly so that it latches
securely.
ON
A
OFF
C
B
D
Содержание 185 CFM
Страница 8: ...N o t f o r R e p r o d u c t i o n 8 ALLMAND COM L B C F A K G E D J H I N M ...
Страница 35: ...N o t f o r R e p r o d u c t i o n 35 Data Adjustment Procedure ...
Страница 37: ...N o t f o r R e p r o d u c t i o n 37 ...
Страница 38: ...N o t f o r R e p r o d u c t i o n 38 ALLMAND COM ...
Страница 39: ...N o t f o r R e p r o d u c t i o n 39 Wiring Diagram ...
Страница 40: ...N o t f o r R e p r o d u c t i o n 40 ALLMAND COM Piping Diagram Air Piping Compressor Oil Piping ...
Страница 41: ...N o t f o r R e p r o d u c t i o n 41 Air Piping Compressor Oil Piping ...
Страница 48: ...N o t f o r R e p r o d u c t i o n ...