Disassembly:
For the
pre-heating nozzle (9)
,
unscrew clamp screw (43)
and pull
pre-heating nozzle (9)
off the
hot air duct (44)
.
Assembly:
Push
pre-heating nozzle (9)
onto the
hot air duct (44)
.
Make sure that it is aligned parallel to the nozzle shoe.
Tighten
clamp screw (43)
.
Three different
pre-heating nozzles (9)
corresponding
to the weld seam width are available. The nozzle cross
sections correspond to the DVS guidelines.
Nozzle 1
Seam width
to 15 mm
Nozzle 2
Seam width
16 to 20 mm
Nozzle 3
Seam width
21 to 40 mm
Pre-heating nozzles for extruders with external air duct
Changing the pre-heating nozzle
9
44
43
Leister Technologies AG offers the right welding shoes for all common types of seam in various sizes:
Blank
V Seam
Fillet
weld
Overlap
seam
Corner
seam
outside
Corner
seam
short
Corner
seam
long
Angled adapter
WELDPLAST S2 / WELDPLAST S2-TPO
with integrated air duct
WELDPLAST S2 / WELDPLAST S2-PVC
with external air duct
Welding shoe range
45°
Blank
V Seam
Fillet
weld
Overlap
seam
Corner
seam
outside
Corner
seam
short
Corner
seam
long
90°