Specifications 

Sensor Type

 

SONY ICX674

Sensor Shutter Type

 

Progressive Interline 

Image Resolution

 

1936 x 1456 pixels

Pixel Size

 

4.54

μ

m x 4.54

μ

Optical Format

 

2/3 inch

Lens Mount

 

C-mount with adjustable back focus  

Color Sensor Filter Pattern

 

Bayer

Full Resolution Frame Rate

 

40.7 fps

I/O

 

2 isolated inputs, 4 isolated outputs, RS-232 TX/RX,

video auto-iris, motorized iris, focus, and zoom 

Power Requirements

 

Less than 5.3W using a single Gige port 

Less than 6.2W using 2 Gige ports 

Digitization

 

14 Bits

Trigger latency*

 

1.5

μ

Trigger Jitter* 

±

0.5

μ

Operating Temperature

 

0 to 50 Celsius***

Operating Humidity

 

20 to 80% non-condensing

Size and Weight

 

See mechanical diagrams

Hardware Interface Standard

 

IEEE 802.3 1000BASE-T, 100BASE-TX 

Software Interface Standard

 

GigE Vision Standard 1.0

Regulatory

 

Conforms to CE, FCC, RoHS

 

 

Applies to GX1920C only. 

††

 

Power consumption will increase with reduced ROI imaging, vertical binning, and color formats.   

See Notes on Triggering in the Addendum. 

 

 

***DUE TO THE SMALL PACKAGING AND HIGH SPEED OF THE GX CAMERAS, SPECIAL CARE IS REQUIRED TO 

MAINTAIN A REASONABLE OPERATING TEMPERATURE.  IF THE CAMERA IS TO BE OPERATED IN A WARM 
ENVIRONMENT, IT IS SUGGESTED THAT THE CAMERA BE MOUNTED ON A HEAT SINK SUCH AS A METAL BRACKET 
AND THAT THERE IS SUFFICIENT AIR FLOW. 

 

Содержание GX1920

Страница 1: ...GX1920 GX1920C Allied Vision Technologies Canada Inc 101 3750 North Fraser Way Burnaby BC V5J 5E9 Canada Technical Manual 700061A October 29 2010 ...

Страница 2: ... Mechanical 8 Connections 9 Cleaning the Sensor 15 Adjusting the C mount 16 Network Card Configuration 17 GigE Sample Viewer and Filter Driver 21 Trouble Shooting 22 Addendum 25 GX IO Schematic 26 User Trigger Circuit Example 27 TV Zoom Lens Connection 28 Video Iris Connection 29 Trigger Timing Diagram 30 Notes on Triggering 31 Camera Controls 33 ...

Страница 3: ... utilisateurs au Canada Cet appareil numérique est conforme aux normes classe A pour bruits radioélectriques spécifiées dans le Règlement sur le brouillage radioélectrique Life support applications These products are not designed for use in life support appliances devices or systems where malfunction of these products can reasonably be expected to result in personal injury Allied Vision Technologi...

Страница 4: ...adtroda Germany Tel 49 36428 677 0 Fax 49 36428 677 28 e mail info alliedvisiontec com Allied Vision Technologies Canada Inc 101 3750 North Fraser Way Burnaby BC V5J 5E9 Canada Tel 1 604 875 8855 Fax 1 604 875 8856 e mail info alliedvisiontec com Allied Vision Technologies Inc 38 Washington Street Newburyport MA 01950 USA Toll Free number 1 877 USA 1394 Tel 1 978 225 2030 Fax 1 978 225 2029 e mail...

Страница 5: ... Poor packaging of this product can cause damage during shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltage polarity and signal integrity prior to powering this device CLEANING This product can be damaged by some volatile cleaning agents Avoid cleaning the image sensor unless absolutely necessary Please see instructions on ...

Страница 6: ...Trigger Jitter 0 5μs Operating Temperature 0 to 50 Celsius Operating Humidity 20 to 80 non condensing Size and Weight See mechanical diagrams Hardware Interface Standard IEEE 802 3 1000BASE T 100BASE TX Software Interface Standard GigE Vision Standard 1 0 Regulatory Conforms to CE FCC RoHS Applies to GX1920C only Power consumption will increase with reduced ROI imaging vertical binning and color f...

Страница 7: ...g edge falling edge any edge level high level low Exposure Time 10 microseconds to 60 seconds in 1 microsecond increments Gain 0 to 24dB Region of Interest ROI independent x and y control with 1 pixel resolution Horizontal Binning 1 to 8 pixels Vertical Binning 1 to 8 rows Pixel Formats Mono8 Mono16 Bayer8 Bayer16 Rgb24 Yuv444 Bgr24 Rgba32 Bgra32 Bayer12Packed Sync Out Modes trigger ready trigger ...

Страница 8: ...GX1920 Technical Manual Page 8 Mechanical GX C MOUNT ...

Страница 9: ...GX1920 Technical Manual Page 9 Connections GX CONNECTION DIAGRAM ...

Страница 10: ...e HR10A 10R 12PB connector on the camera side The mating cable connector is Hirose HR10A 10P 12S This connector can be purchased from AVT Canada Inc or from http www digikey com An open ended cable assembly can also be ordered from AVT Canada Inc Part number 02 6033A See Addendum for more detail POWER GROUND This is the main ground of the camera circuitry and will be the return path for the extern...

Страница 11: ...C INPUTS 1 and 2 The input signals allow the camera to be synchronized to some external event These signals are optically isolated and require the signal common USER GROUND The camera can be programmed to trigger on the rising or falling edge of these signals The camera can also be programmed to capture an image at some programmable delay time after the trigger event These signals can be driven fr...

Страница 12: ... USER SYNC OUT USER TRIGGER CIRCUIT T4 CAMERA CIRCUIT T2 TLP281 4GB 1 2 16 15 T3 IF 5mA CAMERA LOGIC SIGNAL 3 3V CAMERA LOGIC SIGNAL SYNC OUT SIGNAL T1 Various USER VCC values and load values for the above circuit are indicated in the following table USER VCC USER ICC R LOAD V LOAD R POWER DISSIPATION T1 T2 T3 T4 5V 8mA 500Ω 4 1V 32mW 1 5μs 6 5μs 2μs 14μs 5V 4 8mA 1KΩ 4 8V 23mW 1 5μs 5μs 17μs 40μs...

Страница 13: ...power ground If these signals are used in the system care must be taken to prevent ground loop problems USER GROUND This connection provides the user ground reference and return path for the isolated sync in and sync out signals This connection is necessary if any of the isolated sync signals are to be used It is also recommended that this ground connection be physically close to the used sync sig...

Страница 14: ...f 6V up to 12V or lenses which operate with bipolar voltages from 6V up to 12V This voltage level can be controlled through software The default voltage will be set to 6V The current capacity for each axis is 50mA CARE MUST BE TAKEN NOT TO EXCEED THE LENS MANUFACTURERS VOLTAGE SPECIFICATION This connector also provides the signals necessary to operate a video auto iris type of lens The lens contro...

Страница 15: ...lly using a small flat head screw driver Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OIL FROM FINGERS CAN DAMAGE FRAGILE OPTICAL COATINGS Cleaning with Air If it is determined that debris is on the sensor window then remove the camera lens and blow the sensor window directly with clean compressed air If c...

Страница 16: ...s loose unthread the ring a few turns from the camera face A wrench suitable for this procedure can be provided by AVT Canada Inc P N 11 0048A Image to Infinity Use a c mount compatible lens that allows an infinity focus Set the lens to infinity and image a distant object The distance required will depend on the lens used but typically 30 to 50 feet should suffice Make sure the lens is firmly thre...

Страница 17: ... a single data channel 1 Install a dual port network card in the host computer To achieve full camera performance you should use a Gigabit Ethernet card that supports Jumbo frames of at least 9KB size 2 Once installed open your Network Connections Start Control Panel Network Connections and right click on one of the two network connection corresponding to the card that was just installed 3 Select ...

Страница 18: ...ca GigE filter driver this step is not required 8 Perform Steps 1 8 for the other Ethernet adapter port that will be dedicated to the GX camera network 9 The next section will provide instructions for configuring the Link Aggregate Group LAG to combine the two ports dedicated to the GX network Open your Network Connections Start Control Panel Network Connections and right click on one of the two n...

Страница 19: ...ext to continue 14 The LAG group will now be configured You may be asked to permit the AVT_Prosilica GigE Vision Filter Miniport installation on the new LAG adapter Click Continue Anyway 15 Once completed the properties of the TEAM LAG that has just been created will appear A new Network Connections Icon corresponding to the LAG group is created You have now completed the Link Aggregate Group conf...

Страница 20: ...GX1920 Technical Manual Page 20 16 Reboot the system and install GigE Sample Viewer ...

Страница 21: ...ower Verify that the Green LED is a solid green Run Sample Viewer It will take a few seconds for the camera to be recognized especially if your camera is in DHCP mode If the camera does not appear after one minute see the Trouble Shooting section of this document o In Sample Viewer select the wrench icon to change camera settings See the Camera Controls Addendum for description of each setting Sel...

Страница 22: ...IP address range If your NIC has no access to a DHCP server the camera will still be auto assigned an IP address There should be no gateway on your NIC Connect a single camera directly to your NIC no hub switch and run the prosilica IP Configuration utility Start Programs Prosilica GigEIPConfig or C Program Files Prosilica GigEViewer ipconfig exe You may need to wait up to 30 sec for camera to app...

Страница 23: ...nshot to support alliedvisiontec com Ipconfig all screenshot Is the camera listed in SampleViewer but can t acquire images Reset your camera settings to factory default with ConfigFileIndex Factory click the ConfigFileLoad button While streaming check your Stats All stats 0 while streaming Firewall likely blocking traffic All stats 0 Likely a firewall is blocking incoming traffic Disable your fire...

Страница 24: ... your PacketSize setting to 1500 All packets completing as normal but black image Check ExposureValue ExposureMode and be sure your scene is suitably lit If you are still having problems acquiring images please send your camera settings file click on the disk icon in SampleViewer to support alliedvisiontec com Saving camera setting file ...

Страница 25: ...GX1920 Technical Manual Page 25 Addendum ...

Страница 26: ... 1 10W IF 5mA TLP281 4GB 1 2 16 15 TLP281 4GB 3 4 14 13 5V TO 24V IF 5mA VDD 3 3 442R 442R 5V TO 24V IF 5mA 100K SYNC OUT 4 CAMERA LOGIC SY NC OUT 4 D S G MMBF4393LT1G 3 3V LOGIC SYNC OUT 1 D S G MMBF4393LT1G PIN 2 EXTERNAL POWER IF 5mA CAMERA LOGIC SY NC OUT 1 PIN 11 SY NC IN 2 100K 100K IF 5mA VDD 3 3 SYNC OUT 2 VCC GND NC7WZ14P6X 1 3 6 4 5 2 PIN 6 SYNC OUT 1 PIN 8 RS 232 RXD SYNC OUT 3 VCC GND ...

Страница 27: ... SIDE USER GND SY NC OUT 2 EXTERNAL POWER SY NC OUT 4 1K NOTES 1 CAMERA POWER 5V TO 24V 2 CAMERA POWER DOES NOT NEED TO BE THE SAME AS USER VCC 3 CAMERA GND DOES NOT NEED TO CONNECT TO USER GND 4 USER VCC MUST HAVE CURRENT CAPACITY TO SUPPLY IC CURRENT FOR EACH SYNC OUT USED USER LOGIC SY NC OUT 3 POWER GROUND 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12S 1 2 3 4 5 6 7 8 9 10 11 12 USER LOGIC SY...

Страница 28: ...S ZOOM FOCUS COMMON HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 TV ZOOM LENS UNIPOLAR TYPE ZOOM IRIS IRIS TV ZOOM LENS BIPOLAR TYPE HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 IRIS COMMON COMMON COMMON COMMON NOTES 1 CURRENT CAPACITY PER AXIS 50mA 2 VERIFY LENS VOLTAGE SETTING ON CAMERA DOES NOT EXCEED LENS VOLTAGE SPECIFICATION IRIS IRIS ...

Страница 29: ...tion VIDEO AUTO IRIS LENS HIROSE 3240 8P C 50 1 2 3 4 5 6 7 8 LENS POWER POWER GROUND POWER GROUND VIDEO SIGNAL 12V_POWER JEITA CONNECTOR 1 2 3 4 LENS GROUND 1 2 3 4 12V POWER 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12S 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 30: ...GX1920 Technical Manual Page 30 Trigger Timing Diagram ...

Страница 31: ...en the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when the camera image sensor is either exposing and or reading out data o Idle is high if the camera image sensor is not exposing and or reading out data Rules o The User Trigger pulse width should be at least three times th...

Страница 32: ...ering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detected o In this case Trigger Latency and Trigger Jitter can be up to 1 line time since Exposure must always begin on an Interline boundary ...

Страница 33: ...GX1920 Technical Manual Page 33 Camera Controls For the latest up to date camera controls see AVT Camera and Driver Attributes pdf at http www alliedvisiontec com ...