Figure 10. Network card advanced settings.
o
Set Maximum Frame Size or Jumbo Frames to the maximum possible value. A typical
value is 9000. If the list contains a property called Receive Descriptors, then change this
value to its maximum value. Select OK to save properties.
o
From the main properties dialog as in Figure 9, make sure that only the Internet Protocol
(TCP/IP) check box is selected then click OK. The card is now optimized for use with the
Prosilica camera.
o
Open the viewer and set the PacketSize to 8228.