GC1600 User Manual 

 

70-0022A-D

 

AVT Inc. 

 

 

9

Cleaning the Sensor 

 

DO NOT CONTACT CLEAN SENSOR UNLESS ABSOLUTELY NECESSARY. 

Identifying Debris 

Debris on the image sensor or optical components will appear as a darkened area or smudge on 
the image that does not move as the camera is moved.  Do not confuse this with a pixel defect 
which will appear as a distinct point. 

Locating Debris 

Before attempting to clean the image sensor, it is important to first determine that the problem is 
due to debris on the sensor window.  To do this you should be viewing a uniform image, such as 
a piece of paper, with the camera. Debris will appear as a dark spot or dark region that does not 
move as the camera is moved.  To determine that the debris is not on the camera lens, rotate the 
lens independent of the  camera.   If the spot moves as the lens moves, then the object is on the 
lens  -not  on  the  image  sensor-  and  therefore  cleaning  is  not  required.    If  the  camera  has  an  IR 
filter,  then  rotate  the  IR  filter.    If  the  object  moves  then  the  particle  is  on  the  IR  filter  not  the 
sensor.    If  this  is  the  case  remove  the  IR  filter  carefully  using  a  small  flat  head  screw  driver.   
Clean  both  sides  of  the  IR  filter  using  the  same  techniques  as  explained  below  for  the  sensor 
window. 

 

DO  NOT  TOUCH  ANY  OPTICS  WITH  FINGERS.    OIL  FROM  FINGERS  CAN 
DAMAGE FRAGILE OPTICAL COATINGS. 

 

Cleaning with Air 

If it is determined that debris is on the sensor window, then remove the camera lens, and blow 
the sensor window directly with clean compressed air.  If canned air is used, do not shake or tilt 
the  can  prior  to  blowing  the  sensor.  View  a  live  image  with  the  camera  after  blowing.    If  the 
debris  is  still  there,  repeat  this  process.    Repeat  the  process  a  number  of  times  with  increased 
intensity  until  it  is  determined  that  the  particulate  cannot  be  dislodged.  If  this  is  the  case  then 
proceed to the contact cleaning technique. 

Contact Cleaning 

Only  use  this  method  as  a  last  resort.    Use  99%  laboratory  quality  isopropyl  alcohol  and  clean 
cotton swabs.  Dampen the swab in the alcohol and gently wipe the sensor in a single stroke.  Do 
not reuse the same swab.  Do not wipe the sensor if the sensor and swab are both dry. You must 
wipe the sensor quickly after immersion in the alcohol, or glue from the swab will contaminate 
the sensor window.  Repeat this process until the debris is gone.  If this process fails to remove 
the debris, then contact Prosilica. 

 

 

Содержание Prosilica GC1600

Страница 1: ...Allied Vision Technologies Canada Inc 101 3750 North Fraser Way Burnaby BC V5J 5E9 Canada USER MANUAL April 7 2010 GC1600 GC1600C...

Страница 2: ...s 2 Supported Features 3 Mechanical 4 Connections 5 Cleaning the Sensor 9 Adjusting the C mount 10 Camera Installation 11 System Optimization 16 Trouble Shooting 18 Addendum 21 GC IO Schematic 22 Isol...

Страница 3: ...uring shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltage polarity and signal integrity prior to powering this device CLEANIN...

Страница 4: ...ed I O Tpd 10ns for non isolated I O 1 3us for isolated I O Operating Temperature 0 to 50 Celsius Operating Humidity 20 to 80 non condensing Size 33mm height x 46mm width x 59mm length Weight 97g Hard...

Страница 5: ...falling edge any edge level high level low Exposure Time 10 microseconds to 60 seconds in 1 microsecond increments Gain 0 to 21dB Region of Interest ROI independent x and y control with 1 pixel resol...

Страница 6: ...0022A D AVT Inc 4 Mechanical 57 8 26 12 39 5 42 5 26 M3 4MM DEEP 4 PLCS TYP 45 7 33 All dimensions are in mm Add 0 3mm for color cameras due to the addition of IR blocking filter Figure 1 GC SERIES m...

Страница 7: ...GC1600 User Manual 70 0022A D AVT Inc 5 Connections 2 1 4 3 Figure 2 GC SERIES connection diagram...

Страница 8: ...ar view 12 Sync Output 2 non isolated The General Purpose I O port uses a Hirose HR10A 10R 12PB connector on the camera side The mating cable connector is Hirose HR10A 10P 12S This connector can be pu...

Страница 9: ...a will accept a trigger signal Trigger Input A relay of the trigger input signal used to daisy chain the trigger signal for multiple cameras Readout Valid when camera is reading out data Imaging Valid...

Страница 10: ...on with Power Ground however it is good practice to provide a separate ground connection for power and signaling when designing the cabling Video Iris This signal can be used to drive the video input...

Страница 11: ...carefully using a small flat head screw driver Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OIL FROM FINGER...

Страница 12: ...he camera When the locking ring is loose unthread the ring a few turns from the camera face A wrench suitable for this procedure can be provided by Prosilica P N 11 0048A Image to Infinity Use a c mou...

Страница 13: ...owever typical Jumbo Frames are around 9000 bytes Frame size is the number of bytes per packet and the larger the frame size the less the computer CPU will be loaded due to the processing of incoming...

Страница 14: ...t came with the network card o Once the driver is installed open the Network Connections Dialog as follows From the Windows desktop select start then select Control Panel then double click on the Netw...

Страница 15: ...IP address of 169 254 x y where x and y can be any number Press the TAB key after entering the IP address and the subnet mask will automatically be entered The subnet mask is 255 255 0 0 Click OK to s...

Страница 16: ...ble the Firewall for this device Click OK to save changes Gigabit Ethernet Cabling All Gigabit Ethernet cabling and connectors should be CAT5E or CAT6 compatible Cable lengths must not exceed 100 mete...

Страница 17: ...ecognized If the camera does not appear in the Viewer list after approximately 10 seconds then try disconnecting and reconnecting the power If it still does not appear restart the viewer If it still d...

Страница 18: ...anel then double click on the Network Connections icon Double click the relevant network card listed or right click the relevant network card and select Properties This will open the properties window...

Страница 19: ...If the list contains a property called Receive Descriptors then change this value to its maximum value Select OK to save properties o From the main properties dialog as in Figure 9 make sure that onl...

Страница 20: ...cabling known to work Configure your NIC as outlined in Gigabit Ethernet Setup For Windows It should have an IP address of 169 254 x x Subnet Mask 255 255 0 0 This is the AutoIP address range If your...

Страница 21: ...same subnet as your NIC Camera is not listed or flashing Camera Unavailable There may be multiple NICs on your system set to the same subnet The camera can not know which card to resolve to Change th...

Страница 22: ...ware trigger event to capture frames Packets are incoming but all dropping Be sure you have JumboFrames enabled on your NIC Otherwise decrease your PacketSize setting to 1500 All packets completing as...

Страница 23: ...GC1600 User Manual 70 0022A D AVT Inc 21 Addendum...

Страница 24: ...2 RXD MOCD207M FAIRCHILD 1 2 3 4 8 7 6 5 SYNC INPUT 1 VDD 3 3 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10R 12PB 1 2 3 4 5 6 7 8 9 10 11 12 CAMERA INTERNAL CIRCUIT RS232 RXD LOGIC SYNC INPUT 2 SYNC OUTP...

Страница 25: ...POWER R1 2 7K ISOLATED GROUND 5V RECOMMENDED VALUES 12V POWER 12V_POWER 12V SYNC OUTPUT 1 RECEIVER 0 CABLE SIDE 1K 0 7K POWER GROUND R2 POWER GROUND 24V This circuit assumes a 10mA drive current IF f...

Страница 26: ...1 2 3 4 5 6 7 8 9 10 11 12 POWER GROUND SYNC OUTPUT 2 3 3V RECEIVER CABLE SIDE POWER GROUND SYNC INPUT 2 12V_POWER The non isolated trigger circuit is connected to a Texas Instruments SN74LVC2G241 buf...

Страница 27: ...C AVT Inc 25 Video Iris Schematic JEITA CONNECTOR 1 2 3 4 POWER GROUND 12V_POWER LENS GROUND LENS POWER 12V POWER POWER GROUND 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12S 1 2 3 4 5 6 7 8 9 10 11...

Страница 28: ...C AVT Inc 26 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency Interline Time Expose Start Delay Trigger Jitter Idle Registered Exposure Tim...

Страница 29: ...when the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when the camera image...

Страница 30: ...iggering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detected o In this cas...