GC1380 Technical Manual
Page 24
Non-isolated Trigger Schematic
SY NC OUTPUT 2
SY NC INPUT 2 (3.3V DRIVER)
USERS TRIGGER CIRCUIT
12V POWER
1
2
3
4
5
6
7
8
9
10
11
12
HIROSE HR10A-10P-12S
1
2
3
4
5
6
7
8
9
10
11
12
POWER GROUND
SY NC OUTPUT 2 (3.3V RECEIVER)
CABLE SIDE
POWER GROUND
SY NC INPUT 2
12V_POWER
The non-isolated trigger circuit is connected to a Texas Instruments SN74LVC2G241 buffer/driver inside the camera. The required sync input
current is less than 10uA and the maximum sync output current is 24mA. See the Texas Instruments SN74LVC2G241 for more detailed
information.