Advanced parameters and commands
Goldeye Technical Manual
V2.2.0
73
Bad pixel correction (C, F)
The configuration of the
bad pixel correction
is executed ex factory, therefore
no access on behalf of the user is necessary.
The bad pixel correction applies up to six non-false neighbor pixels, in order to
determine an interpolated value from the neighbors. At the position of the bad
pixel an interpolated value in exchange of the bad pixel value is output.
The parameter
F
controls the operation mode of the bad pixel correction.
The following value assignment is applied:
Example
Activate the bad pixel correction.
>
F=1[CR]
By means of parameter
C
the file number of the required correction data is indi-
cated. Ex-factory the bad pixels are determined one time and the corresponding
correction data is stored in a special data format in the camera. As generally
only one file with correction data exists in the camera, it is not necessary to
change this parameter.
Example
Initialization of the correction data for the bad pixel correction from the file
0x70.
>
C=70[CR]
Value
Description
0
Bad pixel correction deactivated;
output of the uncorrected data.
1
Bad pixel correction is applied.
2
Testing mode, output of correc-
tion data. (*)
Table 38: Parameter F: values
Note
(*) Operation mode
2
exists for test purposes.
If you activate this mode, the module does not transmit any
incoming image data. The module is a data source itself
instead.
Содержание Goldeye CL-008 SWIR
Страница 35: ...Start up Goldeye Technical Manual V2 2 0 35 Note For more information see Chapter Image processing on page 54...
Страница 50: ...Data interface Goldeye Technical Manual V2 2 0 50 Figure 17 Timing diagram Goldeye xy 008 320x160...
Страница 51: ...Data interface Goldeye Technical Manual V2 2 0 51 Figure 18 Timing diagram Goldeye xy 032...