Number of lines (N)
The number of lines per frame is controlled with
N
. The actual line count is
N
+1, thus the default of
N=6BD
results into 1726 output lines. Valid values
range from
N=0
to
N=6BD
. If the double ROI mode is active (
D=1
) the actual
line count is doubled: (
N
+ 1) * 2.
Timing examples for parameter settings
M=0
,
S=0
[t
L
= 3 μs],
D=0
:
Timing examples for parameter settings
M=0
,
S=1
[t
L
= 1.5 μs],
D=0
(
not
for Bonito CL-400B/C 200fps cameras):
Note
•
Consider this in minimum frame duration calculations for
the image on demand (IOD) mode.
•
For more information about calculation of the minimum
frame duration and dependent IOD mode timing con-
straints, see Chapter
Exposure control mode (M)
on page
40.
•
See also the other ROI parameters
A
,
B
,
D
and
I
.
Setting
No. of lines Minimum frame
duration t
FDmin
Frame rate/fps
N=6BD
1726
5.181 ms
193.01
N=681
1666
5.001 ms
199.96
N=14B
332
0.999 ms
1001.0
N=1F
32
0.099 ms
10101
N=0
1
0.006 ms
166667
Table 16: Timing examples (M=0, S=0, D=0)
Setting
No. of lines Minimum frame
duration t
FDmin
Frame rate/fps
N=6BD
1726
2.5905 ms
386.03
N=681
1666
2.5005 ms
399.92
N=14B
332
0.4995 ms
2002.0
N=1F
32
0.0495 ms
20202
N=0
1
0.0030 ms
333333