Configuration of the camera
STINGRAY Technical Manual
V2.2.0
295
Pulse-width modulation (PWM): Stingray
housing and board level cameras
Note
L
•
A profile save operation automatically disables captur-
ing of images.
•
A profile save or restore operation is an uninterruptable
(atomic) operation. The write response (of the asyn-
chronous write cycle) will be sent after completion of
the operation.
•
Restoring a profile will not overwrite other settings
than listed above.
•
If a restore operation fails or the specified profile does
not exist, all registers will be overwritten with the
hard-coded factory defaults (profile #0).
•
Data written to this register will not be reflected in the
standard memory channel registers.
Note
L
See
Table 29: PWM configuration registers
on page 89.