Allied Telesis x600 Series Скачать руководство пользователя страница 1

613-001065 Rev. B

x600 Series 
Layer 3 Gigabit 
Ethernet Switches

x600-24Ts
x600-24Ts/XP
x600-48Ts
x600-48Ts/XP

Installation Guide

Содержание x600 Series

Страница 1: ...613 001065 Rev B x600 Series Layer 3 Gigabit Ethernet Switches x600 24Ts x600 24Ts XP x600 48Ts x600 48Ts XP Installation Guide...

Страница 2: ...espective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein i...

Страница 3: ...is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Opera...

Страница 4: ...4 Translated Safety Statements Important The indicates that a translation of the safety statement is available at www alliedtelesis com in a document entitled Translated Safety Statements 613 000990...

Страница 5: ...ns 15 x600 24Ts Switch 15 x600 24Ts XP Switch 16 x600 48Ts Switch 17 x600 48Ts XP Switch 18 10 100 1000Base T Twisted Pair Ports 19 Connector Type 19 Speed 19 Duplex Mode 19 Maximum Distance 19 Cable...

Страница 6: ...air and Fiber Optic Ports 51 Powering on a Switch 52 Starting a Local Management Session 53 Warranty Registration 54 Chapter 4 Troubleshooting 55 Power LED is Off 56 Twisted Pair Port Link LED is Off...

Страница 7: ...Layer 3 Gigabit Ethernet Switches This preface contains the following sections Product Documentation on page 8 Starting a Management Session on page 9 Safety Symbols Used in this Document on page 10...

Страница 8: ...mentation For overview information about the software features of the AlliedWare PlusTM Operating System Software which runs on the x600 Series Switches refer to AlliedWare PlusTM Operating System Sof...

Страница 9: ...uctions that describe how to start a local management session on an x600 switch refer to the Starting a Local Management Session on page 53 For information that describes how to log onto the AlliedPlu...

Страница 10: ...s the safety symbols defined in Table 1 Table 1 Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data Warning Perfor...

Страница 11: ...to Find Web based Guides The installation and user guides for all Allied Telesis products are available in portable document format PDF on our web site at www alliedtelesis com You can view the docum...

Страница 12: ...warranty information go to the Allied Telesis web site at www alliedtelesis com Returning Products Products for return or repair must first be assigned a return materials authorization RMA number A pr...

Страница 13: ...Card Slot on page 24 Port LEDs on page 25 System LEDs on page 27 Stack LEDs on page 28 Terminal Port on page 30 Secure Digital LEDs on page 29 AT RPS3204 Redundant Power Supply on page 31 AT LBM Modu...

Страница 14: ...console port and a redundant power supply connector In addition the x600 24Ts XP and the x600 48Ts XP switches have two XFP transceiver slots On the back of all the switches there is an AC power conn...

Страница 15: ...AT StackXG Stacking Module Figure 1 shows the front panel of the x600 24Ts switch Figure 2 shows the back panel of the x600 24Ts switch Figure 1 x600 24Ts Switch Front Panel Figure 2 x600 24Ts Switch...

Страница 16: ...24Ts XP switch Figure 4 shows the back panel of the x600 24Ts XP switch Figure 3 x600 24Ts XP Switch Front Panel Figure 4 x600 24Ts XP Switch Back Panel 1 3 5 7 9 11 13 15 17 19 21R 23R 2 4 6 8 10 12...

Страница 17: ...e 5 shows the front panel of the x600 48Ts switch Figure 6 shows the back panel of the x600 48Ts switch Figure 5 x600 48Ts Front Panel Figure 6 x600 48Ts Back Panel FDX HDX COL D C 1000 LINK ACT 10 10...

Страница 18: ...s of the x600 48Ts XP switch Figure 8 shows the back panel of the x600 48Ts XP switch Figure 7 x600 48Ts XP Switch Front Panel Figure 8 x600 48Ts XP Switch Back Panel FDX HDX COL D C 1000 LINK ACT 10...

Страница 19: ...and Auto Negotiate the duplex mode setting You can disable Auto Negotiation on one or all of the switch ports so that you can set the duplex mode manually through the AlliedWare PlusTM Operating Syst...

Страница 20: ...ant and feature auto MDI MDI X This feature available when a port s speed and duplex mode are set through Auto Negotiation automatically configures a switch port to MDI or MDI X depending on the wirin...

Страница 21: ...vices over large distances using fiber optic cable SFP tranceivers are also available with a copper cable interface allowing a host device designed primarily for optical fiber communications to also c...

Страница 22: ...FP 10 Gigabit Ethernet transceivers to connect high speed 10 gigabit devices to the switch or create high speed backbone networks between switches Figure 10 shows an example of an XFP transceiver Figu...

Страница 23: ...e end node The twisted pair port automatically changes to the redundant status mode when the SFP module establishes a link with the end node The twisted pair port automatically transitions back to the...

Страница 24: ...f the switch The x600 switches support various SD cards that are available from many vendors To insert an SD card position it so that the manufacturer s brand label is facing up and press it into the...

Страница 25: ...48Ts XP faceplates the twisted pair port LEDs are interspersed among the twisted pair ports Table 3 describes the LEDs for the 10 100 1000Base T twisted pair ports 1312 x600 24Ts XP Layer 3 Gigabit E...

Страница 26: ...he port only applies when operating at 10 or 100 Mbps half duplex mode Table 3 Twisted Pair Port LEDs Continued LED Function State Description Table 4 SFP Slot LED LED Function State Description L A L...

Страница 27: ...for instructions on how to troubleshoot a problem MASTER Off The switch is not a member of an enhanced stack or has an enhanced stacking status of slave or unavailable Green The switch has an enhanced...

Страница 28: ...established a link to a stacking port on another AT StackXG Stacking Module Flashing Green Stack Port 1 has established a link to a stacking port on another AT StackXG Stacking Module and is sending...

Страница 29: ...defined in Table 8 Table 8 Secure Digital LED LED Function State Description SD Link Status and Activity Flashing amber Indicates a fault has been detected The SD card is not valid or a read or write...

Страница 30: ...th a terminal emulation program to the port The terminal port has an RJ 45 style connector An RJ 45 to RS 232 management cable is supplied with the switch The terminal port is set to the following spe...

Страница 31: ...n fully populated with AT PWR3202 Power Supplies the AT RPS3204 unit can support up to four x600 switches simultaneously The AT RPS3204 Redundant Power Supply Module is hot swappable with the x600 swi...

Страница 32: ...e is installed in the expansion slot of the x600 48Ts XP switch For an illustration see Figure 8 on page 18 This module provides a nonblocking switching configuration when there are connections on the...

Страница 33: ...33 AC Power Connector The x600 switches have a single AC power supply socket on the back panel which has autoswitch AC inputs To power the switch on or off connect or disconnect the power cord Refer t...

Страница 34: ...Chapter 1 Overview 34...

Страница 35: ...stall an x600 switch The chapter contains the following sections Reviewing Safety Precautions on page 36 Unpacking a Switch on page 38 Installing the Power Cord Retaining Clip on page 39 Installing th...

Страница 36: ...possibility of electric shock disconnect electric power to the product before connecting or disconnecting the LAN cables E1 Warning Do not work on equipment or cables during periods of lightning activ...

Страница 37: ...ment par une batterie du m me type ou de type quivalent recommand e par le constructeur Les batteries doivent tre limin es conform ment aux instructions du constructeur E22 Warning Mounting of the equ...

Страница 38: ...unit to Allied Telesis 2 Place the switch on a level secure surface 3 Make sure the following components are included in your switch package If any item is missing or damaged contact your Allied Teles...

Страница 39: ...ower Cord Retaining Clip 2 Install the clip on the AC power connector on the back panel of the switch With the u of the clip facing down press the sides of the clip toward the center and insert the sh...

Страница 40: ...remove the snap on plastic feet from the bottom of a switch You can leave the feet on 1 Place the switch upside down on a level secure surface 2 Using a flat head screwdriver remove the snap on plast...

Страница 41: ...ACT PORT ACTIVITY 26 25 L A XFP XFP L A D C D C L A L A STACK PRES MSTR L A 1 2 SFP 1 3 5 7 9 11 13 15 17 19 21R 23R 2 4 6 8 10 12 14 16 18 20 22R 24R FAULT RPS MASTER PWR STATUS 21 22 23 24 SFP L A B...

Страница 42: ...x600 switch perform the following procedure 1 Locate the RESET button which is on the right hand side of the faceplate 2 Press the RESET button with the tip of a pen or a similar nonconducting object...

Страница 43: ...k cables to an x600 switch The chapter contains the following sections Twisted Pair and Fiber Optic Cable Specifications on page 44 Installing Optional Transceivers on page 46 Cabling the Twisted Pair...

Страница 44: ...auto MDI MDI X feature A port where Auto Negotiation has been disabled defaults to MDI X Disabling Auto Negotiation may require manually configuring a port s MDI MDI X setting or using a crossover ca...

Страница 45: ...rnet Switch Installation Guide 45 Optional Transceiver Cable Specifications The cable specifications for an optional SFP or XFP transceiver can be found in the transceiver s installation guide that is...

Страница 46: ...you do remove the plug keep it for future use Unnecessary removal and insertion of a transceiver can lead to premature failure Warning A transceiver can be damaged by static electricity Be sure to obs...

Страница 47: ...24Ts and x600 24Ts XP switches verify that the handle on the SFP transceiver is in the upright position as shown in Figure 24 to prevent inadvertently removing the transceiver Figure 24 Positioning H...

Страница 48: ...Figure 25 Figure 25 Positioning SFP Handles on the x600 48Ts and x600 48Ts XP Switches 7 Repeat this procedure to install another SFP transceiver or go to Cabling the Twisted Pair and Fiber Optic Por...

Страница 49: ...r and store the packaging material in a safe location 3 Position the transceiver with the label facing down 4 Slide the transceiver into the slot until it clicks into place Figure 27 Installing an XFP...

Страница 50: ...Ports 50 5 Repeat this procedure to install a second XFP transceiver or go to Cabling the Twisted Pair and Fiber Optic Ports on page 51 For XFP optical and cabling specifications consult the document...

Страница 51: ...where two or more network devices can communicate with each other over more than one network path do not connect the network cables forming the loop until you have activated a Spanning Tree Protocol o...

Страница 52: ...the Up Position 2 Plug the power cord into the AC power connector on the back panel of the unit see Figure 29 Figure 29 Connecting the AC Power Cord 3 Connect the other end of the power cord to an app...

Страница 53: ...switch to the Terminal Port on the front panel of the switch as shown in Figure 30 Figure 30 Connecting the Management Cable to the RJ 45 Terminal Port on the Switch 2 Connect the other end of the ca...

Страница 54: ...Chapter 3 Cabling the Network Ports 54 Warranty Registration For warranty information go to the Allied Telesis web site at www alliedtelesis com...

Страница 55: ...iver is Installed but the Status is Not Present on page 59 System Fault LED is Blinking on page 60 System Fault LED is Steadily On on page 61 Cannot Establish a Local Out of Band Management Session on...

Страница 56: ...ollowing Make sure the power cord is securely connected to the power source and to the AC connector on the back panel of the switch Verify that the power outlet has power by connecting another device...

Страница 57: ...and duplex mode manually the port defaults to MDI X Disabling Auto Negotiation may require manually configuring a port s MDI MDI X setting or using a crossover cable Make sure that the operating param...

Страница 58: ...r an SFP transceiver refer to the installation instructions shipped with the module Check that the operating specifications for instance wavelength and maximum operating distance of the fiber optic po...

Страница 59: ...n a transceiver slot but the Uplink Information menu in the AlliedWare PlusTM Operating System Software interface displays Not Present for that port do the following Verify that the transceiver is com...

Страница 60: ...he switch is updating the active boot configuration file or a new version of the operating system software is in the process of being downloaded to the switch The LED stops blinking after the switch h...

Страница 61: ...et the switch by disconnecting and reconnecting the AC power cord If the FAULT LED remains ON download a new version of the switch s operating system software For instructions refer to the AlliedWare...

Страница 62: ...do the following Check that the RJ 45 serial management cable is securely connected to the serial terminal port on the switch and to the RS 232 port on the terminal or personal computer Check that th...

Страница 63: ...nctions Intermittently If a switch functions intermittently check the system hardware status through the management interface Note the current voltage for the power supply compared to the optimum rati...

Страница 64: ...Chapter 4 Troubleshooting 64...

Страница 65: ...5 mm 1 72 in x 17 34 in x 12 0 in Weight x600 24Ts 3 86 kg 8 50 lb x600 24Ts XP 4 35 kg 9 60 lb x600 48Ts 4 88 kg 10 75 lb x600 48Ts XP 4 90 kg 10 80 lb Recommended Minimum Ventilation on All Sides 10...

Страница 66: ...m 50 60 Hz Certifications EMI Emissions FCC Class A ICES 003 Class A EN55022 Class A EN61000 3 2 EN61000 3 3 VCCI Class A C TICK CE EMC Immunity EN55024 Electrical and Laser Safety EN60950 1 TUV EN608...

Страница 67: ...configuration at 10 or 100 Mbps Table 11 lists the pin signals when a port is operating in the MDI X configuration at 10 or 100 Mbps The MDI MDI X setting is established automatically when a port is...

Страница 68: ...Technical Specifications 68 Table 12 lists the pin signals when a port operating at 1000 Mbps Table 12 Pin Signals 1000 Mbps Pinout Pair 1 Pair 1 2 Pair 1 3 Pair 2 4 Pair 3 5 Pair 3 6 Pair 2 7 Pair 4...

Страница 69: ...l Port Pinouts Table 13 lists the pin signals on the RJ 45 style serial terminal port Table 13 RJ 45 Style Serial Terminal Port Pin Signals Pin Signal 4 Data Carrier Detect 3 Transmit Data 6 Receive D...

Страница 70: ...mbo Connector and Port Pin Layout Table 14 lists the definitions for the RPS 21 pin D combo port and connector pins 10 20 1 11 11 10 20 A1 1 A1 Table 14 RPS 21 pin Connector Pin Definitions Pin Defini...

Страница 71: ...00 Layer 3 Gigabit Ethernet Switch Installation Guide 71 16 Ground 17 Ground 18 12 0 VDC sense 19 Ground 20 No connect A 1 12 0 VDC Table 14 RPS 21 pin Connector Pin Definitions Continued Pin Definiti...

Страница 72: ...Appendix A Technical Specifications 72...

Отзывы: