C613-50170-01 Rev B
Command Reference for x510 Series
2761
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
T
RIGGER
C
OMMANDS
TRIGGER
ACTIVATE
trigger activate
Overview
This command is used to manually activate a specified trigger from the Privileged
Exec mode, which has been configured with the
trigger
command from the Global
Configuration mode.
Syntax
trigger activate <
1-250
>
Mode
Privileged Exec
Usage
This command manually activates a trigger without the normal trigger conditions
being met.
The trigger is activated even if it is configured as inactive. The scripts associated
with the trigger will be executed even if the trigger is in the diagnostic test mode.
Triggers activated manually do not have their repeat counts decremented or their
'last triggered' time updated, and do not result in updates to the '[type] triggers
today' counters.
Example
To manually activate trigger
12
use the command:
awplus#
trigger activate 12
Related
Commands
Parameter
Description
<
1-250
>
A trigger ID.