Rapier Switch

C613-04017-01 REV F

System LEDs

System LEDs on its front panel indicate the switch’s operational status. 

1.   DC models of the Rapier Switch do not have an RPS connector and the RPS LED will not function.
2.   Not included on the Rapier 48, G6, G6F-SX/SC, G6F-LX/SC, or G6F-SX/MT-RJ.
3.   Hot swapping is supported by Software Release 2.3.1 or later. AT-AR021 (S) BRI-S/T, AT-AR021 (U) 

BRI-U, and AT-AR023 SYN PICs can be hot swapped.

The

 Rapier Switch Hardware Reference

 has further troubleshooting information, 

including information on Switch Port and Uplink Module LEDs.

System LEDs

 

LED

State

Function

Power

Green

The switch is receiving power and the voltage 
is within the acceptable range

Fault

Red

The switch or management software is 
malfunctioning

1 flash

A switch fan has failed. (The LEDs will not 
indicate an RPS fan failure.)

3 flashes

If an RPS is connected, the switch’s PSU (Power 
Supply Unit) has failed

4 flashes

If RPS monitoring is enabled, the RPS PSU has 
failed

5 flashes

If RPS monitoring is enabled, an RPS is not 
connected or is not operational

RPS

1

 (Redundant 

Power Supply)

Green

An RPS is connected to the switch

In use

2

 (Rear panel)

Green

An NSM is installed, is receiving power, and is 
operational. The NSM and its PICs are not 
ready to be hot swapped

Off

No NSM is installed, or the NSM is not installed 
correctly (the switch unit has not recognised 
the NSM)

Swap

(Rear panel)

Green

The NSM and its PICs are ready to be hot 
swapped

Off

The Hot Swap button must be pressed before 
the NSM or PICs can be hot swapped, or the 
software release does not support hot 
swapping

3

Содержание Rapier 24i

Страница 1: ...RAPIER SWITCH QUICK INSTALL GUIDE ...

Страница 2: ...ent without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesyn has been advised of known or should have k...

Страница 3: ...updates can be downloaded from www alliedtelesyn co nz support rapier Rapier Switch Safety and Statutory Information Quick Install Guide Hardware Reference Software Reference Network Service Module NSM Quick Install Guide NSM Hardware Reference Port Interface Card PIC Quick Install Guide PIC Hardware Reference General Customer Support Visit www alliedtelesyn co nz for the latest documentation FAQ ...

Страница 4: ...ck or on a level surface such as a desktop or bench When installing the switch choose a site that Allows adequate airflow around the switch and its vents Is free of dust and moisture Will maintain an ambient temperature range of 0 to 40º C 32 to 104º F and a humidity range of 5 to 95 non condensing Has a reliable and earthed grounded power supply circuit preferably dedicated and filtered Does not ...

Страница 5: ...oose a suitable site for the switch Either a flat surface or 19 inch rack 4 Unpack the switch Verify the package contents If any items are damaged or missing contact your sales representative 5 Install expansion options If you purchased optional Uplink Modules a Network Service Module NSM or Port Interface Cards PICs install them now by following their individual installation guides These guides c...

Страница 6: ...e grounded Circuit protection Use a 10 Amp circuit breaker To connect the DC supply a Ensure the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c At the switch connect the ground wire to the ground terminal The terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0...

Страница 7: ...to light refer to the Rapier Switch Hardware Reference for troubleshooting information 10 Connect the Redundant Power Supply Optional AC models of Rapier Switches have a Redundant Power Supply RPS connector on their rear panel The Switch is designed to operate with the AT RPS8000 RPS which can be purchased separately Contact your authorised Allied Telesyn distributer or reseller for more informati...

Страница 8: ...onfigure the switch using the command line interface Change the password as soon as possible Leaving the manager account with the default password is a serious security risk Make sure you remember the new password as there is no way to retrieve it if it is lost Use the following command to change the account password set password 4 Load command line interface help files To access CLI help enter se...

Страница 9: ...connected directly or through a LAN The PC should be running Internet Explorer 5 x or Netscape 6 2 2 with JavaScript enabled Internet Explorer can be found on the Documentation and Tools CD ROM that is bundled with your switch If you access the Internet through a proxy server set your browser to bypass the proxy for the IP address you just assigned to the VLAN1 interface Point your web browser at ...

Страница 10: ...e Fault Red The switch or management software is malfunctioning 1 flash A switch fan has failed The LEDs will not indicate an RPS fan failure 3 flashes If an RPS is connected the switch s PSU Power Supply Unit has failed 4 flashes If RPS monitoring is enabled the RPS PSU has failed 5 flashes If RPS monitoring is enabled an RPS is not connected or is not operational RPS1 Redundant Power Supply Gree...

Страница 11: ...software The Rapier Switch User Guide which provides an introduction to the switch s Graphical User Interface and its Layer 2 switching features The Network Service Module Quick Install Guide which outlines the procedure for installing an NSM and the Network Service Module Hardware Reference which provides detailed information on NSMs The Port Interface Card Quick Install Guide which outlines the ...

Отзывы: