background image

USA Headquarters 

|

19800 North Creek Parkway 

|

Suite 200 

|

Bothell 

|

WA 98011 

|

USA 

|

T: +1 800 424 4284 

|

F: +1 425 481 3895

European Headquarters 

|

Via Motta 24 

|

6830 Chiasso 

|

Switzerland 

|

T: +41 91 69769.00 

|

F: +41 91 69769.11

Asia-Pacific Headquarters 

|

11 Tai Seng Link 

|

Singapore 

|

534182 

|

T: +65 6383 3832 

|

F: +65 6383 3830

www.alliedtelesis.com

© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

617-000095  Rev. B

iMAP Express 7112

| integrated Multiservice Access Platform

Ordering Information

iMAP Express Accessories

Model

Description

Part #

Optimized Splitter Chassis    3RU, 4 slot POTS Splitter Chassis 

AT-TN-S004-A

Optimized Splitter Card     24-port Splitter card

AT-TN-S101-A

CPE Attenuator   

ADSL2+ Attenuator

AT-TN-S900-A

SFP – 13dB   

1310nm SM SFP, 13dB Optical Budget

AT-TN-P000-A

SFP – MM   

850nm MM SFP, 12db Optical Budget

AT-TN-P001-A

SFP – 24dB

1550nm, SM SFP, 24dB Optical Budget

AT-TN-P002-A

SFP – 18dB

1310nm, SM SFP, 18dB Optical Budget

AT-TN-P003-A

Optimized Splitter Cable    ADSL24 to High Performance Splitter Cable

AT-TN-C013-A-XX**

Standard Splitter Cable

ADSL24 to Standard Splitter Cable

AT-TN-C018-A-XX**

iMAP Express 7112

Model

Description

Part #

iMAP Express 7112

Fixed 1RU Configuration, 48 ADSL2+ ports

AT-TN-7112-A

iMAP Power Options

Model

Description

Part #

AC Power Kit  

7100 AC power kit

AT-TN-R108-A-YY*

Specifications

Uplinks

2 100BT Ethernet
2 Gigabit Ethernet (SFP)

Physical Characteristics

Dimensions:

44cm x 30cm x 4.45cm
17.4” x 11.9” x 1.75” (W x D x H)

Weight:

8.8lbs

Rack Unit:

Single Rack Unit

Access:

Full Frontal Access

Power Characteristics

Dual -48v DC, -36v DC to -57.7v DC
100-220V AC and 50-60Hz (using Optional AC Power kit)
Max Power:

154W

ADSL Standards

ITU-T G.992.1 (ADSL, S = 1/2, G.DMT, T1.413)
ITU-T G.992.5 (ADSL2+)
Annex A (ONLY)

ADSL Port Specifications 

Interface Type:

RJ21 (Qty 2)

Number of VCs per port:

4

Number of priority queues per VC:

8

Dropped packet counter:

Yes

Full traffic classifier support:

Yes

Full traffic classifier action support: Yes
ARP Filtering:

Yes

Ingress Metering:

Yes (1Mbps increment)

Peak Cell Rate Limiting per VC:

Yes

Ingress Max Burst Size:

64kbps

Egress Max Burst Size:

64kbps

Environmental Specifications

Operating Temp:

-40C to 65C 

Storage Temp:

-40C to 85C 

Relative Humidity: 5% to 95%, non-condensing 

Regulatory Approvals

FCC Part 15 Class A/ANSI C63.4 
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A 
VCCI Class A; ITE/ CISPR 22:1997 Class A 
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A 
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998 
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996 
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995 
EN 300 386 V1.3.1:2001-09/EN 61000-4-5:1995 
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999 
UL/cUL 60950: IEC60950 
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2 
USDA RUS 

Standards and Compliance

IEEE 802.1d,w Rapid Spanning Tree
IEEE 802.1q MEV (Double Tagging)
IEEE 802.1p Traffic Class Expediting
IEEE 802.3ad Link Aggregation
IETF RFC 1112 IP Multicasting/IGMP Snooping v1
IETF RFC 2236 IP Multicasting/IGMP Snooping v2
IETF RFC 3619 EAPS w/ATI Extensions for EPSR
IETF RFC 2131 DHCP
IETF RFC 1350 TFTP

*Where YY 

= 10 for U.S. power cord
= 20 for no power cord
= 30 for U.K. power cord
= 40 for Australia power cord
= 50 for Europe power cord

**Where XX   = 005 for 5 ft

= 010 for 10 ft
= 015 for 15 ft
= 020 for 20 ft
= 030 for 30 ft
= 040 for 40 ft

= 050 for 50 ft
= 060 for 60 ft
= 070 for 70 ft
= 080 for 80 ft
= 090 for 90 ft