Powering On an AC Powered Chassis
To power on an AC powered chassis, perform the following procedure:
1. Make sure that the ON/OFF power switch is in the OFF position, as
shown in Figure 6.
Figure 6. ON/OFF Power Switch in OFF Position
2. Position the power cord retaining clip in the up position, as shown in
Figure 7.
Figure 7. Power Cord Retaining Clip in the Up Position
3. Plug the power cord into the AC power connector on the back of the
chassis, as shown in Figure 8.
Figure 8. Connecting the AC Power Cord
4. Secure the cord by lowering the power cord retaining clip, as shown in
Figure 9.
Figure 9. Securing the Power Cord with the Retaining Clip
POWE
R
FAULT
AT-PW
R14
A
A
T
-CVF
AN
A
100-24
0VAC~
WA
RNIN
G
This unit might h
ave more than one p
ower input
. To
reduce the risk of electric s
hock, disconne
ct all p
ower
inputs be
fore se
rvicing unit.
277
POWE
R
FAULT
AT-PW
R14
A
A
T
-CVF
AN
A
100-2
40VA
C
~
WA
RNIN
G
This unit might h
ave more than one p
ower input
. To
reduce the risk of electric sho
ck, disconnect all p
ower
inputs be
fore se
rvicing unit.
278
POWE
R
FAULT
AT-PW
R14
A
A
T
-CVF
AN
A
100-2
40VA
C
~
WA
RNIN
G
This unit might h
ave more than one p
ower input
. To
reduce the risk of electric sho
ck, disconnect all p
ower
inputs be
fore se
rvicing unit.
279
POWE
R
FAULT
AT-PW
R14
A
A
T
-CVF
AN
A
100-2
40VA
C
~
WA
RNIN
G
This unit might h
ave more than one p
ower input
. To
reduce the risk of electric sho
ck, disconnect all p
ower
inputs be
fore se
rvicing unit.
280
5. Turn the ON/OFF power switch of the installed power supply module to the
ON position, as shown in Figure 10.
Figure 10. ON/OFF Power Switch in ON Position
6. Plug the other end of the power cord to a power outlet.
Refer to “Technical Specifications” on page 2 for power requirements.
Note
Refer to the appropriate
AT-CV5000 Chassis Installation Guide
for
electrical safety and emission information.
Caution
For added power protection to the AT-CV5000 Media Converter
chassis, the two AC power cords should be connected to power sources
that are operating from different power circuits. This will protect the
chassis from a power loss should one of the power circuits fail.
Warning
This unit might have more than one power cord. To reduce the risk of
electric shock, disconnect all power cords before servicing the unit.
Warning
Class I Equipment. THIS EQUIPMENT MUST BE EARTHED. The
power plug must be connected to a properly wired earth ground socket
outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts.
7. Check that the POWER LED on the AT-PWR14 module is green. If the
POWER LED is OFF or the FAULT LED is ON, refer to the
AT-CV5000
Chassis Installation Guide
for troubleshooting instructions.
The chassis is now ready for network operations. No further installation
steps are required if you do not need to change the default parameter set-
tings of the chassis, which are listed in the
AT-S70 Management Software
User’s Guide
. However, if you want to manage the chassis or review the
settings, refer to the
AT-CV5000 Chassis Installation Guide
.
Note
To replace a power supply, refer to the
AT-CV5000 Chassis Installation
Guide
for instructions on how to remove a power supply module from the
chassis.
518
POWE
R
FAULT
A
100-240
VAC
~
WARNING
This un
it might h
reduc
e the risk o
inpu
ts be
fore se
r
Power Switch
to ON
Position
Technical Specifications
Physical and Environmental
Dimensions (H x W x L)
3.67 cm x 10.1 cm x 17.1 cm
1.445 in x 3.973 in x 6.726 in
Operating Temperature
0° C to 40° C (32° F to 104° F)
Storage Temperature
-25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity
5% to 90% RH (non-condensing)
Storage Relative Humidity
5% to 95% RH (non-condensing)
Operating Altitude Range
Up to 3,000 m (9,843 ft)
Electrical Ratings
Input Voltage
100 - 240 V AC, 3.2A maximum
AC Input Frequency
47-63 Hz
Power Consumption
75 watts maximum
Electrical Safety and Emission Statement
Standards
: This product meets the following standards when installed in compliant host equipment.
Emission
FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
WARNING
:
In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
Immunity
EN55024
Electrical Safety
UL60950 (
c
UL
us
), EN60950 (TUV), CSA22.2 No. 950
Copyright
2006 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right
to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur
du Canada.
4
5
6