C613-50102-01 REV C
Command Reference for x510 Series
665
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
P
OWER
OVER
E
THERNET
C
OMMANDS
SHOW
POWER
-
INLINE
INTERFACE
show power-inline interface
Overview
This command displays a summary of Power over Ethernet (PoE) information for
specified ports. If no ports are specified then PoE information is displayed for all
ports.
For information on filtering and saving command output, see the
with AlliedWare Plus” Feature Overview and Configuration Guide
Syntax
show power-inline interface [<
port-list
>]
Mode
User Exec and Privileged Exec
Example
To display the PoE port-specific information for all PoE ports on the switch, use the
following command:
awplus#
show power-inline interface
To display the PoE port specific information for the port range1.0.1 to 1.0.4, use the
following command:
awplus#
show power-inline interface port1.0.1-port1.0.4
Output
Figure 18-4:
Example output from the
show power-inline interface
command
Parameter
Description
<
port-list
>
Enter the PoE port(s) to display PoE specific information in the show
output.
awplus#show power-inline interface port1.0.1-port1.0.4
Interface Admin Pri Oper Power Device Class Max(mW)
port1.0.1 Disabled Low Disabled 0 n/a n/a n/a
port1.0.2 Enabled High Powered 3840 Desk Phone 1 5000 [U]
port1.0.3 Enabled Crit Powered 6720 AccessPoint 2 7000 [C]
port1.0.4 Disabled Low Disabled 0 n/a n/a n/a
Table 3:
Parameters in the
show power-inline interface
command output
Parameter
Description
Interface
The PoE port(s) in the format
portx.y.z
, where
x
is the device
number,
y
is the module number within the device, and
z
is the
PoE port number within the module.
Admin
The administrative state of PoE on a PoE port, either
Enabled
or
Disabled
.