background image

USA Headquarters 

|

19800 North Creek Parkway 

|

Suite 200 

|

Bothell 

|

WA 98011 

|

USA 

|

T: +1 800 424 4284 

|

F: +1 425 481 3895

European Headquarters 

|

Via Motta 24 

|

6830 Chiasso 

|

Switzerland 

|

T: +41 91 69769.00 

|

F: +41 91 69769.11

Asia-Pacific Headquarters 

|

11 Tai Seng Link 

|

Singapore 

|

534182 

|

T: +65 6383 3832 

|

F: +65 6383 3830

www.alliedtelesis.com

© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

617-000114   Rev. B

ADSL24SA 

| AT-TN129-A 24 Port ADSL2+ with Splitters Service Module

ADSL24SA

Model

Description

Part #

ADSL24SA

24 ports, ADSL2+ with Integrated POTS Splitter

AT-TN-129-A

Ordering Information

Interface Specifications

Number of ADSL2+ ports:

24

Number of POTS Splitter ports: 24
Backplane capacity:

1Gbps

Physical design:

Front Access, Dual Slot
2x RJ-21 (Female)

ADSL Standards

ITU-T G.992.1 (ADSL, G.DMT, T1.413)
ITU-T G.992.5 (ADSL2+), S = 1/2
Annex A (ONLY)

POTS Splitter Specifications

Loop Impedence:

600ohms

Compliant to ITU-T 992.1 and T1.413

Port Specifications

Number of VCs per port: 4
Priority queues per VC: 8
Dropped packet counter
Full traffic classifier support
Full traffic classifier action support
ARP Filtering
Ingress Metering:

1Mbps increment

Peak Cell Rate Limiting per VC
Ingress Max Burst Size: 64kbps
Egress Max Burst Size: 64kbps

Protocols and Specifications
IEEE 802.1Q VLAN Bridging
IEEE 802.1p Prioritization
IETF RFC 1112 IP Multicasting/IGMP Snooping v1
IETF RFC 2236 IP Multicasting/IGMP Snooping v2
DHCP Relay Agent option 82 (RFC 3046)

Power Requirements

Maximum Power:

45W

Environmental Specifications

Operating Temp:

-40C to 65C

Storage Temp:

-40C to 75C

Relative Humidity:

5% to 95%, non-condensing

Regulatory Approvals

FCC Part 15 Class A/ANSI C63.4
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
VCCI Class A; ITE/ CISPR 22:1997 Class A
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-5:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999
UL/cUL 60950: IEC60950
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2
USDA RUS

iMAP 9x00 Chassis

Model

Description

Part #

iMAP 9700   

17-slot chassis with DC power with faceplates 

AT-TN-250GF

iMAP 9700    

17-slot chassis with DC power without faceplates

AT-TN-250G

iMAP 9400   

7-slot chassis with DC power with faceplates

AT-TN-251GF

iMAP 9400   

7-slot chassis with DC power without faceplates

AT-TN-251G

MiniMAP 9101   

3-slot mini chassis with DC power

AT-TN-9101-A-80

MiniMAP 9102

3-slot mini chassis with AC power

AT-TN-9102-A-XX*

iMAP Common Control

Model

Description

Part #

CFC24   

24GbE switch controller card 

AT-TN-401-B

GE3    

3x GbE WAN interface card

AT-TN-301-A

CFC12   

12GbE switch controller card

AT-TN-408-A

*Where XX 

= 10 for U.S. power cord
= 30 for U.K. power cord
= 40 for Australia power cord
= 50 for Europe power cord

**Where YY 

= 015 for 15 m
= 025 for 25 m
= 035 for 35 m

Related iMAP Line Cards and Accessories

Model

Description

Part #

POTS24

24-port, POTS Service Module

AT-TN-113-A

PAC24   

24-port, POTS and ADSL2+ Combo Service Module

AT-TN-123-A

MDF Cable   

Optimized to Conventional Cable (male-unterm)

AT-TN-C019-A-YY**

CPE Attenuator

ADSL2+ Attenuator

AT-TN-S900-A

Filler

Full size service slot filler plate

AT-TN-M000-A

Отзывы: