Chapter 2: Ethernet Line Cards
48
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Cable
Requirements
The cable requirements for the ports on the AT-SBx81GT24 and AT-
SBx81GT40 Line Cards are listed in Table 11.
Note
Patch cables for the AT-SBx81GT40 Line Card, in lengths of 1
meter and 3 meters with RJ point 5 and RJ-45 connectors, are
available from Allied Telesis. Contact your Allied Telesis sales
representative for information.
The cable requirements for the PoE ports on the AT-SBx81GP24 Ethernet
Line Card are given in Table 12 on page 49.
Table 11. Twisted Pair Cable for the AT-SBx81GT24 and AT-SBx81GT40
Line Cards
Cable Type
10Mbps
100Mbps
1000Mbps
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes
Yes
No
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes
Yes
Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes
Yes
Yes
Содержание AT-SBx8
Страница 8: ...Contents 8...
Страница 12: ...List of Figures 12...
Страница 14: ...List of Tables 14...
Страница 18: ...Preface 18...
Страница 32: ...Chapter 1 Chassis and Power Supplies 32...
Страница 118: ...Chapter 6 Installing the Power Supplies 118...
Страница 134: ...Chapter 7 Installing the AT SBx81CFC400 Controller and Ethernet Line Cards 134...
Страница 152: ...Chapter 8 Installing the Transceivers and Cabling the Ports 152...
Страница 190: ...Chapter 9 Powering On the Chassis 190...
Страница 212: ...Chapter 11 Troubleshooting 212...
Страница 230: ...Chapter 12 Replacing Modules 230 Figure 146 Lowering the Locking Handle on the Power Supply Slot Cover...