background image

10

SwitchBlade Chassis and Fan Tray

C613-04029-01 REV C

7.

Secure the fan tray

Rotate the ejector levers until both locking mechanisms engage their holes 
in the chassis. 

8.

Install the fan tray faceplate

Place the faceplate over the fan tray so that the plate’s two mounting 
screws line up with the threaded holes on the fan tray (see Figure 6 on 
page -10).

Tighten the mounting screws.

Figure 6: Installing fan tray faceplate.

9.

Check the fan tray’s operation

If the chassis is receiving power and the stand-by switch is in the Run 
position, you should hear the fans running and feel air movement across 
the chassis vents.

10. Attach the cable manager

If you detached a cable manager to install the fan tray, re-attach it now.

A cable manager for the AT-SB4108 (SwitchBlade 8) can be purchased 
separately, contact your authorised Allied Telesyn distributor or reseller for 
more information.

Содержание AT-SB4151

Страница 1: ...SwitchBlade Chassis and Fan Tray Quick Install Guide...

Страница 2: ...o make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall All...

Страница 3: ...e Contents The following items are included with each SwitchBlade chassis These items may arrive in more than one package Contact your sales representative if any items are damaged or missing One Swit...

Страница 4: ...y Blank faceplates for switch controller and line card bays AT SB4193 Blank faceplates for PSU bays AT SB4192 Fan trays AT SB4152 for the SwitchBlade 8 or AT SB4151 for the SwitchBlade 4 Blank facepla...

Страница 5: ...illips 2 screwdriver screws and cage nuts Due to the chassis size and weight it is recommended that you have someone assist you with the rack mounting procedure 3 Choose a suitable site for the switch...

Страница 6: ...6 Insert the blank faceplates if not factory fitted When inserting a faceplate make sure the faceplate s metal back panel is aligned with the card guides see Figure 2 on page 6 Faceplates are mounted...

Страница 7: ...ssis the fan tray will be pre installed in the chassis If you purchased a SwitchBlade fan tray without also purchasing a SwitchBlade chassis the following items are included with each fan tray One fan...

Страница 8: ...authorised Allied Telesyn distributor or reseller An ESD socket is provided on the front panel of the SwitchBlade chassis The socket is designed to be used in conjunction with an ESD wrist strap see...

Страница 9: ...injury or fan damage Figure4 Fan tray ejectors 6 Insert the new fan tray With the fan tray s ejector levers in the unlocked position see Figure 4 on page 9 slide the fan tray into the chassis making s...

Страница 10: ...e 6 on page 10 Tighten the mounting screws Figure 6 Installing fan tray faceplate 9 Check the fan tray s operation If the chassis is receiving power and the stand by switch is in the Run position you...

Страница 11: ...n on the switch and its hardware features The SwitchBlade Software Reference provides detailed information on configuring the switch and its software The SwitchBlade Power Supply Unit Quick Install Gu...

Отзывы: