Quick Install Guide

7

 C613-04049-01 REV B

4.

Connect the positive feed to the + (positive) terminal and the negative 
feed to the - (negative) terminal. Tighten the terminals to between 2.4 
and 4.0 Nm (21.3 and 35.4 lbf in).

Check that the PSU terminals are wired to the correct polarity. A PSU will be 
damaged if incorrectly connected.

5.

Ensure there are no exposed cable strands.

6.

Replace the transparent plastic terminal cover.

The transparent plastic terminal cover must be replaced.

7.

Secure the supply cable (to the rack framework or similar object) so that 
the connections are isolated from any force applied to the cable.

8.

Ensure the circuit breaker (for the supply circuit) and the Run/Standby 
switch (on the switch) are in the OFF position.

9.

Connect the supply cable wires to the circuit breaker.

10. Switch the power switch to the ON position.

9.

Check the PSU LEDs

Each PSU has LEDs that indicate the PSU’s operational status.

Once you have inserted the PSUs and powered on the chassis, check the 
LEDs for correct operation using the table below as a guide (see Table 2).

On the front panel of the switch there are two LEDs that indicate the 
operational status of each PSU installed in the switch (see Table 3).

Table 2: LEDs on AC and DC PSUs

LED

State

Function

Fault

Red

There is either a fan failure, or the temperature has 
exceeded the specified limit of 75º C (167

º F

).

PWR

Green

A PSU is installed and supplying power to the switch.

Содержание AT-PWR01

Страница 1: ...AT PWR01 QUICK INSTALL GUIDE ...

Страница 2: ... in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein e...

Страница 3: ...t pre installed in a AT 8900 Series switch at the factory Contact your sales representative if any items are damaged or missing One AC power cord AC model One power cord retaining clip AC model One Safety and Statutory Information booklet One warranty card AT 8900 Series Printed Acrobat PDF Website Documentation Roadmap AT 8900 Series Safety and Statutory Information Booklet AT 8900 Series Softwar...

Страница 4: ... nz support at8900 2 Gather the tools and equipment you will need To loosen or secure the PSU s mounting screws you will need a Phillips 2 screwdriver To install a DC version of the PSU you will need an appropriate DC power source DC supply cable ring connectors and a crimp tool 3 Unpack the PSU In an antistatic environment remove the PSU from its packing material Be sure to observe ESD precaution...

Страница 5: ...of the switch s power supply bay If you remove a PSU or FOM from the switch replace the PSU or FOM to prevent dust and debris from entering the switch chassis and to maintain proper airflow 6 Insert a PSU Slowly and carefully slide the PSU into the switch s power supply bay Firmly press the PSU home until its front panel engages or nearly engages the switch chassis 7 Secure the PSU Keep the PSU in...

Страница 6: ...stalled only in Restricted Access Areas Dedicated Equipment Rooms Equipment Closets or the like in accordance with Articles 110 16 110 17 and 110 18 of the National Electrical Code ANSI NAPA 70 DC supply cable specifications Three core cable is required Minimum core size 3 3 mm2 12 AWG high strand count copper wire Minimum cable rating 600 V 90 degrees Celsius DC power supply specifications 40 to ...

Страница 7: ...cable 8 Ensure the circuit breaker for the supply circuit and the Run Standby switch on the switch are in the OFF position 9 Connect the supply cable wires to the circuit breaker 10 Switch the power switch to the ON position 9 Check the PSU LEDs Each PSU has LEDs that indicate the PSU s operational status Once you have inserted the PSUs and powered on the chassis check the LEDs for correct operati...

Страница 8: ...Green PSU 1 is installed and supplying power to the switch and the voltage output is within specification Red PSU 1 is installed in the switch a fan has failed or the PSU has exceeded its recommend temperature threshold of 75º C 167º F A FOM is installed in the switch and a fan has failed The bay is empty no PSU or FOM installed Not lit A FOM is installed and the fan is good PSU 2 Green PSU 2 is i...

Страница 9: ...ortant safety information and statutory declarations for AT 8900 Series switches The AT 8900 Series Quick Install Guide which outlines the procedure for installing a AT 8900 Series switch The AT 8900 Series Hardware Reference which includes detailed hardware specifications for the AT 8900 Series switch The AT 8900 Series Software Reference which provides detailed information on configuring the AT ...

Отзывы: