Chapter 4: Installing the Switch and its Power Supplies
72
Starting a Local Management Session
This procedure requires a terminal or a terminal emulator program and the
management cable that comes with the switch. To start a local
management session on the switch, perform the following procedure:
1. Connect the RJ-45 connector on the management cable to the
Console port on the front panel of the switch, as shown below.
Figure 30. Connecting the Management Cable to the Console Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. If you have not already done so, power up the switch as described in
the previous procedures.
2680
S2
/28
S1
/27
26
25
CONSO
LE
SFP
+
Содержание AT-IX5-28GPX
Страница 10: ...Tables 10 ...
Страница 14: ...Preface 14 ...
Страница 60: ...Chapter 3 Beginning the Installation 60 ...
Страница 76: ...Chapter 4 Installing the Switch and its Power Supplies 76 ...
Страница 84: ...Chapter 5 Configuring the Switch for Stand alone Operations 84 ...
Страница 90: ...Chapter 6 Verifying the Status of VCStack and Activating VCStack 90 ...
Страница 116: ...Chapter 9 Cabling the Networking Ports 116 ...
Страница 122: ...Chapter 10 Troubleshooting 122 ...