Chapter 2: Installing the Bridging Converter
34
Planning the Installation
Be sure to observe the following guidelines when planning the installation
of your bridging converter.
The end-node connected to the 1000Base-SX port must be
compatible with the SFP transceiver.
The 10/100/1000Base-T twisted pair port may be set to match the
speed and mode of the connected device or allowed to Auto-
Negotiate.
The end-node connected to a port on the bridging converter can be
any other ethernet network device, such as an adapter card, repeater,
router, hub, or another switch.
The twisted pair cabling must be kept away from sources of electrical
noise, such as radios, transmitters, power lines, broadband
amplifiers, electrical motor, and fluorescent fixtures.
Table 6 lists the twisted pair port cabling specifications.
Table 6. Twisted Pair Cabling and Distance Specifications
Speed
Type of Cable
Maximum
Operating
Distance
10 Mbps
Category 3 or better 100 ohm
shielded or unshielded twisted pair
cable
100 m (328 ft)
100 Mbps
Category 5 or Category 5E
(Enhanced) 100 ohm shielded or
unshielded twisted pair cable
100 m (328 ft)
1000 Mbps
Category 5 or Category 5E
(Enhanced) 100 ohm shielded and
unshielded twisted pair cable
100 m (328 ft)
Содержание AT-GS2002 Series
Страница 1: ...AT GS2002 AT GS2002 SP Gigabit Bridging Converters Installation Guide PN 613 50648 00 Rev A...
Страница 8: ......
Страница 32: ......
Страница 58: ......
Страница 64: ......
Страница 91: ...AT GS2002 Series Installation Guide 91 1 1 2 3 LAN 4 5 6 I 7 8 9 40 C...
Страница 92: ...Appendix C Translated Electrical Safety and Emission Information 92 10 11 15 LAN OFF 12 13 14 15 16 17 18 19...
Страница 93: ...AT GS2002 Series Installation Guide 93 20 21 22 23 24 25 26 UL 600 90 C 14 AWG 27 28 29...
Страница 95: ...AT GS2002 Series Installation Guide 95 41 42 TEL PSTN 43 26 AWG...
Страница 96: ......