background image

Quick Install Guide

3

C613-04038-01 REV F

Models Covered By This Guide

This Quick Install Guide includes information on the following models:

AT-9812T

AT-9812TF

AT-9816GB

AT-9816GF

Quick Install Guide updates can be downloaded from 
www.alliedtelesyn.co.nz/support/at9800/

Package Contents

The following items are included with each AT-9800 Series switch. Contact 
your sales representative if any items are damaged or missing.

One AT-9800 Series switch

One AC power cord (for AC models)

One serial cable for connecting the switch to a terminal or PC

One 19 inch rack-mount kit

One AT-9800 Series Quick Install Guide

One Safety and Statutory Information booklet

One AT-9800 Series Documentation and Tools CD-ROM (which includes 
the complete AT-9800 Series Document Set and utilities)

One warranty card

CAM

AT-9800 Series

Printed

Acrobat PDF

Website

Documentation Roadmap

AT-9800 Series Safety and Statutory Information Booklet

AT-9800 Series Software Reference

AT-9800 Series Hardware Reference

General Customer Support

Visit www.alliedtelesyn.co.nz for 
the latest documentation, FAQs, 
and support information.

AT-9800 Series Quick Install Guide

CAM Quick Install guide

AT-RPS9000 Quick Install Guide

AT-RPS9000 Safety and Statutory Information Booklet

Содержание AT-9800 Series

Страница 1: ...AT 9800 Series Switch Quick Install Guide AT 9812T AT 9812TF AT 9816GB AT 9816GF ...

Страница 2: ...ges in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herei...

Страница 3: ...tch to a terminal or PC One 19 inch rack mount kit One AT 9800 Series Quick Install Guide One Safety and Statutory Information booklet One AT 9800 Series Documentation and Tools CD ROM which includes the complete AT 9800 Series Document Set and utilities One warranty card CAM AT 9800 Series Printed Acrobat PDF Website Documentation Roadmap AT 9800 Series Safety and Statutory Information Booklet AT...

Страница 4: ...itch without exceeding maximum cable length limitations See the AT 9800 Series Hardware Reference for cable length specifications Installing the Switch This equipment must be earthed Follow these steps to install the switch 1 Read the safety information For safety information see the Safety and Statutory Information booklet A copy of this booklet is supplied with each switch and can also be found ...

Страница 5: ...onnector on the switch s rear panel The Fault LED should flash for approximately 10 seconds as the switch runs internal tests If the LED continues to flash or remains lit refer to the AT 9800 Series Hardware Reference for troubleshooting information Figure 1 AT 9816GF front panel and rear panel with AC power inlet CLASS 1 LASER R P S INPUT AC SUPPLY DATA 100 120 200 240 HZ 50 60 AMPS 4 2 Input Vdc...

Страница 6: ...At the switch connect the ground wire to the ground terminal The terminals can be identified by the diagram on the switch s rear panel Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0 055 pound force per foot c At the switch connect the positive feed to the positive terminal and the negative feed to the negative terminal Tighten the terminal to between 0 6 and 0 8 Nm 0 041 to 0 055 pound ...

Страница 7: ...e number of fibre GBICs also installed Table 1 on page 7 lists the number of 1000BASE T GBICs that can be installed in the AT 9816GF for various copper fibre combinations Slide the GBICs into the GBIC slots Press each GBIC firmly into place A range of GBICs have been tested and approved for use with AT 9800 Series switches contact your authorised Allied Telesyn distributor or reseller for more inf...

Страница 8: ... bits 8 Parity None Stop bits 1 Flow control Hardware 3 Check the power supply Ensure that the On Off switch AC models or Run Standby switch DC models is in the On or Run position and that the switch is receiving power Power LED lights green 4 Log in After the switch has booted the log in prompt appears If the log in prompt doesn t appear press Enter two or three times When the switch boots for th...

Страница 9: ...th a supported browser installed JavaScript must be enabled You need to know the PC s subnet 2 Connect the PC to the switch Use an Ethernet cable to connect an Ethernet card on the PC to any one of the switch ports You can browse to the router through any VLAN as long as you give that VLAN an IP address see below These instructions assume you will use vlan1 The switch ports all belong to vlan1 by ...

Страница 10: ...ower Green The switch is receiving power Fault Red The switch or management software is malfunctioning 1 Flash A switch fan has failed or is operating below the recommended speed 2 Flashes If RPS monitoring is enabled an RPS fan has failed or is operating below the recommended speed 3 Flashes If an RPS is connected the switch s PSU Power Supply Unit has failed 4 Flashes If RPS monitoring is enable...

Страница 11: ...y information and statutory declarations for the AT RPS9000 chassis and AT PWR9000 power unit The AT 9800 Series Hardware Reference which provides detailed information on the hardware features of AT 9800 Series switches This Quick Install Guide The AT RPS9000 Quick Install Guide which outlines the procedure for installing AT RPS9000 chassis and AT PWR9000 power units The AT 9800 Series Software Re...

Страница 12: ......

Отзывы: