102
AR Router
C613-03031-01 REV E
Figure 63: Example output from the SHOW LOG command for an AR740 router with an AT-AR061 ECPAC card
installed.
If any PAC tests fail, check that the PAC is correctly installed in its slot and repeat the
tests. Contact your authorised Allied Telesyn distributor or reseller if the PAC does not
operate correctly.
Once the PAC is operating, its functionality can be tested either by using the
Test Facility software, which is built into the router, or by configuring a module
to use the PAC. For more information about configuring interfaces, see the
“Compression and Encryption Services” chapter of your router’s Software
Reference.
Using the Test Facility to Verify Operation
The built-in Test Facility software is the easiest way to verify a PAC’s operation.
See the Test Facility chapter of your router’s Software Reference for more information
about the Test Facility.
To run the Test Facility for a PAC, use the command:
ENABLE TEST INTERFACE=PAC
The test will run for 4 minutes. To view the results of the test at any time, use
the command:
SHOW TEST
Figure 64 on page 103 shows a typical output. The status of the test will be
shown in the right-hand column. For further information on the meanings of
the other figures, see the “Test Facility” chapter of your router’s Software
Reference.
Date/Time S Mod Type SType Message
--------------------------------------------------------------------------
15 00:05:50 4 ENCO ENCO PAC 7751 Found. Initialisation started
15 00:05:50 4 ENCO ENCO PAC 7751 Initialisation Successful
15 00:05:50 7 SYS REST NORM Router startup, ver 2.2.2-00, 18-May-2001,
Clock
Log: 00:04:40 on 15-Jun-2001
15 00:05:53 3 USER USER 00011 manager login failed on port0
15 00:05:58 3 USER USER LON manager login on port0
15 00:05:59 3 CH MSG WARN No patches found
--------------------------------------------------------------------------
Содержание AR Router Series
Страница 1: ...AR SERIES ROUTER HARDWARE REFERENCE...