![ALLIED COMMERCIAL KGA092H4B Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/allied-commercial/kga092h4b/kga092h4b_product-specifications_2901853025.webp)
K-Series Packaged Gas / Electric 7.5 to 12.5 Ton / Page 25
RATINGS
NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
12.5 TON STANDARD EFFICIENCY KGB150S4M (1ST STAGE) - SINGLE ZONE VAV SUPPLY FAN SUPPLY AIR BLOWER
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
65°F
75°F
85°F
95°F
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
cfm
kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F
63°F
2560
68.8
3.41
0.64 0.74 0.84
64.5
3.8
0.63 0.74 0.85
60
4.21
0.62 0.74 0.86
55.3
4.66
0.62
0.75
0.88
3200
74.6
3.44
0.67 0.79 0.91
70.1
3.82
0.67
0.8
0.92
65.2
4.22
0.67
0.8
0.94
60.3
4.68
0.67
0.82
0.96
3480
76.6
3.45
0.69 0.81 0.93
72
3.82
0.69 0.82 0.95
67.2
4.23
0.69 0.83 0.97
61.9
4.68
0.69
0.84
0.99
67°F
2560
74.2
3.44
0.51 0.62 0.71
69.9
3.82
0.5
0.61 0.71
65.4
4.23
0.49
0.6
0.71
60.6
4.69
0.48
0.6
0.72
3200
80
3.46
0.54 0.65 0.76
75.3
3.84
0.53 0.64 0.76
70.6
4.25
0.52 0.65 0.77
65.3
4.7
0.51
0.65
0.78
3480
82.1
3.47
0.55 0.67 0.78
77.5
3.84
0.54 0.66 0.78
72.5
4.25
0.53 0.66
0.8
67.1
4.7
0.52
0.67
0.81
71°F
2560
79.9
3.46
0.41
0.5
0.59
75.6
3.84
0.39 0.49 0.58
70.8
4.24
0.37 0.48 0.58
65.9
4.7
0.35
0.47
0.58
3200
86
3.49
0.42 0.52 0.63
81.4
3.86
0.4
0.52 0.62
76.5
4.27
0.39 0.51 0.63
71.1
4.72
0.37
0.5
0.62
3480
88.2
3.5
0.42 0.53 0.64
83.4
3.87
0.41 0.53 0.64
78.3
4.27
0.4
0.52 0.64
72.9
4.73
0.38
0.52
0.64
12.5 TON STANDARD EFFICIENCY KGB150S4M (2ND STAGE) - SINGLE ZONE VAV SUPPLY FAN SUPPLY AIR BLOWER
Entering
Wet
Bulb
Temper-
ature
Total
Air
Volume
Outdoor Air Temperature Entering Outdoor Coil
85°F
95°F
105°F
115°F
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Dry Bulb
Dry Bulb
Dry Bulb
cfm
kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F kBtuh
kW
75°F 80°F 85°F
63°F
3800
146.9
9.2
0.69 0.84 0.98 135.7 10.21
0.7
0.86
1
124.2 11.34
0.7
0.88
1
111.9 12.62 0.72
0.91
1
4400
153
9.23
0.73 0.89
1
141.3 10.23 0.74 0.91
1
129.5 11.37 0.75 0.94
1
117
12.65 0.77
0.98
1
5000
158
9.26
0.76 0.94
1
146.2 10.27 0.77 0.97
1
134.2
11.4
0.8
0.99
1
121.8 12.67 0.82
1
1
67°F
3800
157.9
9.26
0.54 0.67 0.81 146.4 10.26 0.53 0.68 0.82 134.6 11.39 0.52 0.68 0.84 122.2 12.68 0.51
0.69
0.87
4400
164.1
9.29
0.56 0.71 0.86 152.4
10.3
0.56 0.72 0.88 139.9 11.43 0.55 0.73
0.9
127.1
12.7
0.55
0.75
0.94
5000
169.2
9.32
0.58 0.74 0.91 157.1 10.33 0.58 0.75 0.93 144.6 11.47 0.58 0.77 0.96 131.1 12.73 0.59
0.79
0.99
71°F
3800
169.9
9.32
0.39 0.53 0.65
158
10.34 0.38 0.52 0.65 145.8 11.47 0.37 0.52 0.66 132.7 12.74 0.35
0.51
0.67
4400
176
9.36
0.41 0.55 0.69 163.6 10.36
0.4
0.55
0.7
151.1 11.51 0.38 0.54 0.71 137.4 12.77 0.37
0.54
0.72
5000
180.9
9.39
0.42 0.57 0.72 168.2 10.39 0.41 0.57 0.73 155.3 11.52
0.4
0.57 0.75 141.4 12.79 0.39
0.58
0.77