Command reference
R&S
®
ZND
871
User Manual 1173.9557.02 ─ 61
.............................................................................................899
...............................................................................................900
...........................................................................................900
................................................................................................900
.............................................................................................. 901
................................................................................902
MMEMory:STORe:TRACe:OPTion:BALanced
...................................................................903
MMEMory:STORe:TRACe:OPTion:SYMMetric
..................................................................903
MMEMory:STORe:TRACe:OPTion:COMMent
...................................................................904
MMEMory:STORe:TRACe:OPTion:DECimals:DATA
.......................................................... 904
MMEMory:STORe:TRACe:OPTion:DECimals:STIMulus
.....................................................904
MMEMory:STORe:TRACe:OPTion:FORMat
..................................................................... 904
MMEMory:STORe:TRACe:OPTion:PLUS
......................................................................... 905
MMEMory:STORe:TRACe:OPTion:SSEParator
.................................................................905
MMEMory:STORe:TRACe:OPTion:TABS
......................................................................... 905
MMEMory:STORe:TRACe:OPTion:TRIM
..........................................................................905
................................................................................... 905
MMEMory:AKAL:FACTory:CONVersion
<Directory>
Converts the factory calibration data of the standards in the active calibration unit
(
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess
) to Touchstone format and cop-
ies it to the specified directory.
Setting parameters:
<Directory>
String parameter to specify the directory.
Example:
MMEM:AKAL:FACTory:CONVersion 'C:\Users\Public\
Documents\Rohde-Schwarz\Vna\AKAL\Touchstone'
Convert and copy the factory calibration data of the active cali-
bration unit to the specified (writable) directory.
Usage:
Setting only
Manual operation:
See
MMEMory:AKAL:USER:CONVersion
<Directory>[, <CalKitFile>]
Converts an arbitrary (e.g. user-defined) set of calibration data of the standards in the
active calibration unit (
SYSTem:COMMunicate:RDEVice:AKAL:ADDRess
) to Touch-
stone format and copies it to the specified directory.
Setting parameters:
<Directory>
String parameter to specify the directory.
<CalKitFile>
Name and (possibly) directory of the cal kit file to be used for the
automatic calibration (optional string parameter):
–
If the parameter is omitted, the analyzer uses the last charac-
terized cal kit file.
SCPI command reference
www.allice.de
Allice Messtechnik GmbH