Troubleshooting
15. No Agitation
NOTE: Use the production test mode to help
diagnose this issue. Refer to Production Test
Summary paragraph.
No agitation.
Motor
won't run?
Refer to
Test
Procedures
section
to check switch
and windings.
Yes
Has drive
motor
overload
protector
cycled?
Wait two or three
minutes for
overload protector
to reset. If
protector cycles
repeatedly, refer
to
Paragraph 9
.
Yes
Is there a
bind in
pump?
Replace pump.
No
Yes
Close lid or test
switch and
replace if
inoperative.
Is there
broken, loose
or incorrect
wiring?
Refer to
appropriate
wiring diagram.
Yes
Is lid open
or lid switch
inoperative?
No
Yes
Is
transmission
assembly
inoperative?
Repair or
replace
transmission
assembly.
Yes
Is drive
belt
broken or
loose?
Replace belt.
No
Yes
Are pauses
part of
normal cycle?
Control is
designed to
pause (SOAK)
during
DELICATE
cycle. Allow
completion of
SOAK period.
Yes
No delicate
cycle
agitate?
Refer to
Test
Procedures
section to check
low speed switch
and windings.
No
No
Yes
No
No
No
TLW462S