Step
Test Cycle Step
Display
Description
82
Card Reader Test
"Card Reader"
Machine logic board will
force transition to card reader
display override menu when
necessary to allow card reader
to display during this test step.
Table 21
Individual Diagnostic Tests Menu
Figure 38
The Individual Test Menu allows the user to perform individual
manual diagnostic tests.
To enter the desired test from the Individual Diagnostic Tests
Menu, press the or keypads to highlight and press the
keypad to select. The display shows prompts and results of the
corresponding test. Refer to
To exit the test, press the keypad.
Individual Diagnostic Tests
Test Name
Display
Description
Coin Drop Test
Coin 1: XXX
Coin 2: YYY
X and Y are the number of pulses received
for drop #1 and drop #2. The control ad-
vances to the next test step when the
keypad is pressed.
Start Pulse Test
XXX
XXX is the number of start pulses re-
ceived. This test verifies whether the con-
trol is capable of recognizing an electric
pulse from a central card reader system.
The central card reader system must pro-
vide an electric pulse.
Show Fill Time Test
XXXXXs
XXXXX is the average Wash Fill time in
seconds. “s” is seconds. The average fill
time is calculated by taking the average of
the last ten (10) fill times from start of the
fill until the desired water level is reached.
Table 22
continues...
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
67
Part No. 806526ENR2
Содержание Quantum Platinum