To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
60. CYLINDER DRIVE MOTOR
Reversing Tumblers
Refer to Figure 19.
a. Support drive guard and remove the screws
holding it to the back panel of the tumbler.
b. Loosen locking bolt and back adjusting screw
out to loosen belt. Refer to Figure 25.
c. Slip drive belt off of the motor pulley.
d. Disconnect the wire harness from motor.
e. Remove the four cap screws, nuts, lockwashers
and flat washers holding the motor to the
mounting bracket.
f. Loosen the setscrews in the motor pulley and
remove pulley by using a suitable puller.
NOTE: Refer to wiring diagram when rewiring the
motor.
g. After installing motor, adjust drive belt tension,
and adjust motor position on mounting bracket.
Figure 19
CYLINDER
DRIVE
MOTOR
PULLEY
MOUNTING
BRACKET
SCREW
LOCKWASHER
FLAT
WASHER
ADJUSTING
BOLT
TMB1689P