Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
l. Check gas valve pressure as follows:
(1) Remove pressure tap pipe plug. Refer to
(2) Connect a “U” tube manometer (or similar
pressure gauge) to the pressure tap. Refer
to Figure 46.
(3) Start dryer, pressure should be 10 ± 1.5
inches (25.4, ± 3.8 cm). Refer to Figure 46.
(4) Stop dryer and remove “U” tube and
reinstall the pressure tap pipe plug. Refer to
Figure 43.
m. Check the gas line connection for gas leaks with
a soapy solution.
n. Make sure the dryer conversion has been
completed. Recheck the following:
(1) Installed correct orifice spud (#53), see
step “e”.
(2) Installed block-open plug, see step “g”.
(3) Gas valve pressure must be 10 ± 1.5 inches
(25.4 ± 3.8 cm), see step “l”.
Figure 43
1 - 3
4 5
DRY963S
PRESSURE TAP
PIPE PLUG
APPLY NO. 60517
VALVE CONVERTED
STICKER HERE
BURNER
HOUSING
AIR
SHUTTER
HEX HEAD
SCREW
BURNER
TUBE
IGNITER QUICK
DISCONNECT BLOCKS
VENT
SCREW
SHUT-OFF
VALVE HANDLE
CLOSED
POSITION
OPEN
POSITION
VENT
SCREW
BURNER
ORIFICE
SPUD
TOP VIEW OF
GAS VALVE
Figure 44
DRY964S
APPLY
GAS STICKER
HERE
To reduce the risk of an explosion or fire,
do not use an open flame to check for gas
leaks!
DANGER