![Alliance Laundry Systems ZE1010-1502 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/alliance-laundry-systems/ze1010-1502/ze1010-1502_service-manual_2901222044.webp)
62631
45
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
51. FRONT AIR DUCT
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 13.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 13.
c. Disconnect wires from door switch. Refer to
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Remove two screws from lint filter and lift filter
out of bulkhead. Refer to Figure 16.
NOTE: When installing lint filter, be sure to install
the filter with the word “FRONT” facing the front
of the dryer.
e. Remove four screws holding duct to front
bulkhead and remove air duct. Refer to
Figure 25.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
duct. Refer to Figure 24.
To Test Heater Assembly (Electric Models)
1. Disconnect wires from heater assembly.
NOTE: Refer to appropriate wiring diagram
when rewiring heater assembly.
2. Set meter to read Ohms. Apply meter probes to
the heater assembly terminals. Meter should
read 10.4 Ohms ± .30 Ohms cold.
Figure 25
DRY858S
AIR
DUCT
CABINET
ATTACHING SCREWS
DRY858S
SLOT
PHILLIPS HEAD
SCREWS
HEX
HEAD
SCREWS
HEX
HEAD
SCREWS
SLOT
FRONT