Inverter Drive Error Codes
53
9002101
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
This alarm appears if:
•
The RES signal is on;
•
You attempted to set any
parameter value in the external
operation mode;
•
You attempted to change the
operation mode during operation;
•
You attempted to set any
parameter value outside its setting
range.
•
You attempted to set any
parameter value during operation (while
signal STF or STR is ON).
•
You attempted to set any
parameter value while parameter write
is being inhibited in Pr. 77 “parameter
write inhibit selection”.
Perform operation
correctly.
Under Voltage
The power supply has fallen below a
specified level.
This fault appears
every time the
machine is powered
down.
Check the power
supply voltage.
Apply the proper
voltage to the
machine.
Table 33
Operation
Panel
Indication
Name
Description and NOTES
Check point
Corrective action