42
39201
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
29. CABINET TOP ASSEMBLY
a. Remove two screws from bottom edge of front
panel. Refer to Figure 37.
b. Pull bottom of panel away from washer until
hold down clips (located on top flange of panel)
disengage from slots in cabinet top.
c. METERED MODELS:
(1) Unlock and remove meter case service
door.
(2) Remove timer bracket cap screw. Refer to
(3) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
(4) Remove shoulder screw from inside meter
case.
(5) Remove two cabinet top hold down screws.
Refer to Figure 37.
(6) Remove security bolt (if present) from left
rear corner of cabinet top.
NOTE: When lowering cabinet top into position or
reinstalling cabinet top, pivot outer tub forward far
enough to prevent damaging (bending) loading door
switch lever.
d. Tape loading door closed and lift cabinet top to
a vertical position by hinging it on the rear
hinges.
NOTE: Cabinet top is self supporting, however, a
small chain may be used for additional support.
Refer to Figure 38.
TO REMOVE CABINET TOP FROM
WASHER
a. Remove two control panel attaching screws.
Refer to Figure 5. Lay assembly forward on a
protective pad on cabinet top.
b. Disconnect pressure hose from pressure
switch. Refer to Figure 6.
IMPORTANT: When installing pressure hose, blow
air into hose before connecting hose to switch to
remove any moisture that may have accumulated in
the hose.
c. Push base wire harness block and pressure hose
down through hole in cabinet top.
d. Tape loading door closed.
e. Reinstall control panel and screws.
f. Remove two screws from bottom edge of front
panel. Refer to Figure 37.
g. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
h. METERED MODELS:
(1) Unlock and remove meter case service
door.
(2) Remove timer bracket cap screw. Refer to
(3) Slide timer and bracket toward rear of
meter case to disengage bracket from
shoulder screw. Lift timer and bracket out
of meter case through service door opening
as far as wires will permit.
(4) Remove shoulder screw from inside meter
case.
(5) Remove two cabinet top hold down screws.
Refer to Figure 37.
Figure 38
CHAIN