© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Specifications and Dimensions
9
F8138601
(Continued)
Specifications
35
60
80
100
125
150
Cylinder Speeds / Centrifugal Force Data
1/2 Wash/reverse, rpm (g)
26 (.25)
26 (.31)
26 (.35)
26 (.35)
26 (.40)
23 (.31)
Wash/reverse, rpm (g)
42 (.66)
40 (.73)
40 (.82)
40 (.82)
37 (.82)
36 (0.8)
Distribution, rpm (g)
83 (2.57)
71 (2.29)
73 (2.57)
70 (2.50)
62 (2.29)
61 (2.29)
Very Low extract, rpm (g)
401 (60)
364 (60)
343 (60)
343 (60)
317 (60)
314 (60)
Low extract rpm (g)
568 (120)
514 (120)
485 (120)
485 (120)
449 (120)
444 (120)
Medium extract, rpm (g)
695 (180)
630 (180)
594 (180)
594 (180)
550 (180)
543 (180)
High extract, rpm (g)
803 (240)
727 (240)
686 (240)
686 (240)
565 (190)
627 (240)
Very High extract, rpm (g)
898 (300)
813 (300)
766 (300)
766 (300)
579 (200)
701 (300)
Balance Detection
Vibration switch installed
STD
STD
STD
STD
STD
STD
Direct Steam Heating (Optional)
Steam inlet connection size,
in (mm)
0.5 (13)
0.5 (13)
0.5 (13)
0.5 (13)
0.75 (19)
0.75 (19)
Number of steam inlets
1
1
1
1
1
1
Steam required to
raise bath temperature
10°F, lb (10°C, kg)
LOW
2.1 (1.5)
3.3 (2.4)
4.6 (3.3)
5.7 (4.1)
6.7 (4.9)
8.3 (6.0)
MED
2.3 (1.7)
3.7 (2.6)
5.2 (3.8)
6.5 (4.7)
7.8 (5.6)
9.5 (6.9)
HIGH
2.7 (1.9)
4.1 (2.9)
6.1 (4.4)
7.6 (5.5)
9.1 (6.6)
11.1 (8.0)
Average consumption per cycle,
BHP (kg)
1.4 (21.4)
2.1 (33.4)
3.1 (48.4)
3.8 (60.4)
4.6 (72.0)
5.8 (91.0)
Electrical Heating (Optional)
Total electrical heating capacity,
kW
15.6
27.4
41.2 (Q-Volt)
27.4 (N-Volt)
41.2 (Q-Volt)
27.4 (N-Volt)
N/A
N/A
Number of electrical heating
elements
6
6
9
9
N/A
N/A
Electrical heating element size,
kW
2.6
4.2
4.2
4.2
N/A
N/A
Time required to
raise bath temperature
10°F, min (5°C, min)
LOW
2.4 (3.6)
2.4 (3.7)
2.2 (3.4)
2.8 (4.2)
N/A
N/A
MED
2.7 (4.1)
2.7 (4.1)
2.5 (3.9)
3.2 (4.8)
N/A
N/A
HIGH
3.1 (4.7)
3.0 (4.6)
3.0 (4.5)
3.7 (5.6)
N/A
N/A