© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
13
1800001
Gas Connection
IMPORTANT: The installation must comply with
local codes, the current National Fuel Gas Code,
ANSI Z223.1 in the U.S.A., or the current CAN/
CSA B149, Installation Codes in Canada.
Install a shut-off valve to isolate gas connections from
rest of installation. Gas models must be connected to
the existing gas pipes. The gas supply pipe size must
have sufficient dimensions to minimize pressure loss.
Obtain specific gas supply pipe size from the gas
supplier. Refer to
for general pipe size.
When connecting to a gas line, an equipment shut-off
valve must be installed within 6 feet (1.8 m) of the
finisher. A 1/8 inch N.P.T. pipe plug must be installed
as shown. Refer to
.
Gas Pipe Size Required for 1,000 BTU Natural Gas
0.64 Specific Gravity at 6.5 ± 1.5 inch (1.62 ± .37 kPa) Water Column Pressure
EQUIVALENT LENGTH
Gas
Appliances
Total Btu/hr.
25 feet
(7.63 m)
50 feet
(15.25 m)
75 feet
(22.88 m)
100 feet
(30.50 m)
125 feet
(38.13 m)
150 feet
(45.75 m)
Based on 0.3" Water Column Pressure Drop for Length Given
100,000
.75 in.
(19.05 mm)
.75 in.
(19.05 mm)
1 in.
(25.4 mm)
1 in.
(25.4 mm)
1 in.
(25.4 mm)
1 in.
(25.4 mm)
200,000
1 in.
(25.4 mm)
1 in.
(25.4 mm)
1.25 in.
(31.8 mm)
1.25 in.
(31.8 mm)
1.25 in.
(31.8 mm)
1.25 in.
(31.8 mm)
300,000
1 in.
(25.4 mm)
1.25 in.
(31.8 mm)
1.25 in.
(31.8 mm)
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
400,000
1 in.
(25.4 mm)
1 in.
(25.4 mm)
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
2 in.
(50.8 mm)
500,000
1 in.
(25.4 mm)
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
600,000
1.5 in.
(38.1 mm)
1.5 in.
(38.1 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
700,000
1.5 in.
(38.1 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2.5 in.
(63.5 mm)
800,000
1.5 in.
(38.1 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2.5 in.
(63.5 mm)
2.5 in.
(63.5 mm)
900,000
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2.5 in.
(63.5 mm)
2.5 in.
(63.5 mm)
2.5 in.
(63.5 mm)
1,000,000
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2 in.
(50.8 mm)
2.5 in.
(63.5 mm)
2.5 in.
(63.5 mm)
2.5 in.
(63.5 mm)
IMPORTANT: For L.P. (Liquefied Petroleum) gas, correct the total BTU/hour by multiplying it by 0.6. The
answer is the equivalent BTU on the above chart.
Table 5
Содержание UL15F069
Страница 2: ......