background image

hot and cold water. Warm water temperature is dependent upon
the water temperature and the pressure of both the hot and cold
water supply lines.

WARNING

To prevent personal injury, avoid contact with inlet
water temperatures higher than 51° Celsius [125°
Fahrenheit] and hot surfaces.

W748

Water pressure must be a minimum of 138 to a maximum of 827
kPa [minimum of 20 to a maximum of 120 pounds per square
inch] static pressure measured at the faucet.

NOTE: Water pressure under 138 kPa [20 pounds per
square inch] will cause an extended fill time in the
washer.

Turn on the water supply faucets and flush the lines for approxi-
mately two minutes to remove any foreign materials that could
clog the screens in the water mixing valve. This is especially im-
portant when installing your washer in a newly constructed or
renovated building. Build-up may have occurred during construc-
tion.

 Connecting Hoses

1.   Remove the two plain rubber washers and two filter screens

from the accessories bag.

2.   Install them into each end of the fill hoses as shown in 

Figure

. The screen must be facing outward.

3.   Screw hose couplings with the filter screens onto the water

faucets until they are finger-tight. Use the red color-coded
hose for the hot water connection and the blue color-coded
hose for the cold water connection.

4.   Then, using a pliers, screw approximately 1/4 turn.
5.   Screw hose couplings from other end of hoses onto the water

mixing valve until they are finger-tight. Make sure the red
color-coded hose from the hot water faucet goes to the water
mixing valve marked “H” and the blue color-coded hose from
the cold faucet goes to the valve marked “C”. Refer to Figure 

Figure 4 

.

6.   Then, using a pliers, screw approximately 1/4 turn.

IMPORTANT: DO NOT cross thread or overtighten
couplings. This will cause them to leak.

7.   Turn water on and check for leaks.
8.   If leaks are found, turn off the water, unscrew hoses and rein-

stall them until there are no leaks.

IMPORTANT: Turn off water supply whenever there
will be an extended period of non-use.

TLW1988N_SVG

HOT

COLD

8

7

6

5

4

3

2

1

1.  

Filter Screen (Screen must be facing outward)

2.  

Fill Hose

3.  

Rubber Washer (Plain)

4.  

Cold Water Connection

5.  

Hot Water Connection

6.  

Install this end of hose to valve connections at rear of
washer.

7.  

Install this end of hose to water supply faucet.

8.  

Faucet

Figure 4

IMPORTANT:
Hoses and other rubber parts deteriorate after exten-
ded use. Hoses may develop cracks, blisters or materi-
al wear from the temperature and constant high pres-
sure they are subjected to.

All hoses should be checked on a monthly basis for
any visible signs of deterioration. Any hose showing
the signs of deterioration listed above should be re-
placed immediately. All hoses should be replaced ev-
ery five years.

 Connect Drain Hose to Drain

Receptacle

1.   Remove the drain hose from its shipping position on the rear

of the washer by unhooking the hose from the retainer clamp.

2.   Install the drain hose into the drain receptacle (standpipe, wall

or laundry tub) following the instructions below.

NOTE: Drain receptacle must be capable of handling
a minimum of 32 mm [1-1/4 inch] outside diameter
drain hose.

 Standpipe Installation

1.   Check standpipe height. The recommended height for the

standpipe is 914 mm [36 inches]. Standpipes higher than 1220
mm [4 feet] will result in slower draining and may extend cy-
cle times.

NOTE: Machine will not drain if standpipe is higher
than 2438 mm [8 feet].

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  7

  Part No. 204300ENR3

Содержание TR5104WN

Страница 1: ...oad Washers Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machi...

Страница 2: ......

Страница 3: ...lation 7 Low Standpipe Installation 8 Wall Installation 8 Laundry Tub Installation 8 Position and Level the Washer 9 Plug In the Washer 9 Electrical Requirements 10 Earth Ground Instructions 10 Check...

Страница 4: ...ic Control 1048 mm 41 25 in Knob Control 1035 mm 40 75 D 1346 mm 53 in E 660 mm 26 in F 10 mm 0 4 in G 651 mm 25 63 in H 737 mm 29 in I 1086 mm 42 75 in J 914 mm 36 in With leveling legs turned into b...

Страница 5: ...iameter Smaller inside diameter hoses will cause long fill times which could create nuisance fill errors The two plain rubber washers and two filter screens included with the washer in the accessories...

Страница 6: ...each for several minutes This will release any accumula ted hydrogen gas The gas is flammable Do not smoke or use an open flame during this time W029 Mixing Valve Flow Rates Pressure kPa psi HOT lite...

Страница 7: ...e Figure 4 6 Then using a pliers screw approximately 1 4 turn IMPORTANT DO NOT cross thread or overtighten couplings This will cause them to leak 7 Turn water on and check for leaks 8 If leaks are fou...

Страница 8: ...or 40 mm 1 1 2 in Diameter 4 914 mm 36 in Recommended Height 5 305 mm 12 in Figure 5 Low Standpipe Installation If standpipe is lower than 914 mm 36 inches you must install No 562P3 Siphon Break Kit...

Страница 9: ...el from side to side and front to back 6 If washer is not level tilt washer back to access the front lev eling legs Loosen the locknuts and adjust legs by screwing into or out of washer base 7 Once ad...

Страница 10: ...three prong earth ground plug on the power cord should be plugged directly into a polarized three slot effective earth ground receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Fi...

Страница 11: ...ve earth ground have a qualified electri cian or your local electrical utility company check it and cor rect any problems WARNING This unit is equipped with a three prong earth ground plug for your pr...

Страница 12: ...Wipe Out Inside of Washtub TLW2281N_SVG1 6 Plug In the Washer TLW2289N_SVG CHECK CHECK 3 Connect Fill Hoses TLW1988N_SVG HOT COLD 7 Check Lid Lock CHECK CHECK 4 Connect Drain Hose to Drain Receptacle...

Отзывы: