background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

5

M412060

Important Safety Instructions 

(Save These Instructions)

1. Read all instructions before using the tumbler.

2. Refer to the GROUNDING INSTRUCTIONS 

in the INSTALLATION manual for the proper 
grounding of the tumbler.

3. Do not dry articles that have been previously 

cleaned in, washed in, soaked in, or spotted with 
gasoline, dry-cleaning solvents, other flammable 
or explosive substances as they give off vapors 
that could ignite or explode.

4. Do not allow children to play on or in the 

tumbler. Close supervision of children is 
necessary when the tumbler is used near children. 
This is a safety rule for all appliances.

5. Before the tumbler is removed from service or 

discarded, remove the door to the drying 
compartment.

6. Do not reach into the tumbler if the cylinder is 

revolving.

7. Do not install or store the tumbler in an area 

where it will be exposed to water and/or weather.

8. Do not tamper with the controls.

9. Do not repair or replace any part of the tumbler, 

or attempt any servicing unless specifically 
recommended in the user-maintenance 
instructions or in published user-repair 
instructions that you understand and have the 
skills to carry out.

10. Do not use fabric softeners or products to 

eliminate static unless recommended by the 
manufacturer of the fabric softener or product.

11. To reduce the risk of fire, DO NOT DRY plastics 

or articles containing foam rubber or similarly 
textured rubberlike materials.

12. Keep area around the exhaust opening and 

adjacent surrounding area free from the 
accumulation of lint, dust and dirt.

13. The interior of the tumbler and the exhaust duct 

should be cleaned periodically by qualified 
service personnel.

14. If not installed, operated and maintained in 

accordance with the manufacturer’s instructions 
or if there is damage to or mishandling of this 
product’s components, use of this product could 
expose you to substances in the fuel or from fuel 
combustion which can cause death or serious 
illness and which are known to the State of 
California to cause cancer, birth defects or other 
reproductive harm.

15. Tumbler will not operate with the loading door 

open. DO NOT by-pass the door safety switch by 
permitting the tumbler to operate with the door 
open. The tumbler will stop tumbling when the 
door is opened. Do not use the tumbler if it does 
not stop tumbling when the door is opened or 
starts tumbling without pressing or turning the 
START mechanism. Remove the tumbler from 
use and call the serviceman.

16. Do not put articles soiled with vegetable or 

cooking oil in the tumbler, as these oils may not 
be removed during washing. Due to the 
remaining oil, the fabric may catch on fire by 
itself.

17. To reduce the risk of fire, DO NOT put cloths 

which have traces of any flammable substances 
such as machine oil, flammable chemicals, 
thinner, etc. or anything containing wax or 
chemicals such as in mops and cleaning cloths, or 
anything dry-cleaned at home with dry-cleaning 
solvent in the tumbler.

18. Use the tumbler only for its intended purpose, 

drying clothes.

19. ALWAYS disconnect the electrical power to the 

tumbler before attempting service. Disconnect 
power by shutting off appropriate breaker or fuse.

20. Install this tumbler according to the 

INSTALLATION INSTRUCTIONS. All 
connections for electrical power, grounding, and 
gas supply must comply with local codes and be 
made by licensed personnel when required. Do 
not do it yourself unless you know how!

21. Remove laundry immediately after the tumbler 

stops.

To reduce the risk of fire, electric shock, 
serious injury or death to persons when 
using your tumbler, follow these basic 
precautions:

W054

WARNING

Содержание Stacked Drying Tumbler

Страница 1: ...on Operation Maintenance Stacked Drying Tumbler Models with Electronic Control Part No M412060R2 May 2006 Keep These Instructions For Future Reference If this tumbler changes ownership be sure this ma...

Страница 2: ......

Страница 3: ...taller service agency or the gas supplier W052 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W053 WARNING POUR VOTRE...

Страница 4: ...models are not certified in Australia NOTE The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be under...

Страница 5: ...ion 11 Materials Required 11 Facilities Required 11 Layout 11 Floor 11 Shipping Braces 11 Venting 11 Individual Venting 12 Combined Exhaust Manifold Venting 12 Collector Venting 12 Individual Exhaust...

Страница 6: ...COPY or TRANSMIT 4 M412060 Preventive Maintenance Instructions 33 Daily 33 Lint Removal 33 Monthly 33 Lubrication 33 Lint Removal 33 Every Six Months 35 Lint Removal and Cylinder Belt Inspection 35 D...

Страница 7: ...talled operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you to substance...

Страница 8: ...he cylinder with a damp cloth to remove particles of fiberglass 24 Always follow the fabric care instructions supplied by the garment manufacturer 25 Never operate the tumbler with any guards and or p...

Страница 9: ...l numbers will be found on the nameplate as shown Replacement Parts Information If replacement parts are required contact the source from whom you purchased your tumbler or contact the Ripon Service P...

Страница 10: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 8 Notes...

Страница 11: ...for service access Sides 0 in 0 cm permitted 31 5 8 in 80 3 cm 31 5 8 in 80 3 cm 20 3 4 in 62 7 cm 33 3 4 in 85 7 cm 42 5 8 in 108 3 cm 43 1 2 in 110 5 cm 46 1 2 in 118 1 cm 28 1 4 in 71 8 cm 4 5 32 i...

Страница 12: ...50 1 17 3 Amp 2 wire grounded system Line 1 Neutral Ground 240 50 1 10 Amp 2 wire grounded system Line 1 Neutral Ground 220 60 1 10 Amp 2 wire grounded system Line 1 Neutral Ground Energy Data 63 000...

Страница 13: ...er square foot 488 kg square meter Floor covering materials such as carpeting or tile should be removed Shipping Braces To facilitate installation the shipping braces located on the lower left and rig...

Страница 14: ...y to the outdoors a main collector duct may be used if it is sized according to Figure 4 These illustrations indicate minimum diameters and should be increased if the collector length exceeds 20 feet...

Страница 15: ...in 76 2 cm Minimum Clearance Figure 2 2 in 5 1 cm Minimum Clearance 30 in 76 2 cm Minimum Clearance 2 in 5 1 cm Minimum Clearance 2 in 5 1 cm Minimum Clearance No Screen or Cap Wall Air Out Inspectio...

Страница 16: ...fold Construction Figure 3 TMB2155N 10 in 25 4 cm Inside Diameter 17 50 in 44 5 cm 36 10 in 91 7 cm 2 in 5 1 cm TYP Standard Stove Pipe Crimp 6 in 15 2 cm Inside Diameter 2 Places Rivet to Duct 8 Rive...

Страница 17: ...tted for First 4 in 10 2 cm 12 in 30 5 cm Minimum Clearance 0 in Clearance Permitted for First 4 in 10 2 cm 2 in 5 1 cm Minimum Clearance No Screen or Cap Wall NOTE Maximum length of exhaust duct is 1...

Страница 18: ...unscrew the four shipping capscrews one at each corner and lift the tumbler from the skid The leveling legs will be in a bag inside the cylinder Screw the four leveling legs into the level adjusting...

Страница 19: ...e Figure 5 TMB2157N Clearance of tumbler cabinet from combustible construction must be a minimum of 12 inches 30 5 cm at top W647 WARNING NOTE Shaded areas indicate adjacent structure 0 in Clearance P...

Страница 20: ...st be done by installing a one inch 2 54 cm pipe gas loop as shown in Figures 8 and 9 Before connecting the gas piping to the tumbler make certain gas service is the same as that specified on the seri...

Страница 21: ...e compound resistant to actions of L P gas on all pipe threads To reduce the risk of fire or explosion The tumbler and its individual shut off valve must be disconnected from the gas supply piping sys...

Страница 22: ...0 1 25 40 1 25 40 1 25 31 75 1 25 31 75 1 5 38 10 1 5 38 10 2 50 80 2 50 80 2 50 80 2 50 80 2 50 80 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 2 5 63 50 3 76 20 3 76 20 3 76 20 3 76 2...

Страница 23: ...mblers Gas Line Pressure Tap IMPORTANT Gas loop piping must be installed as illustrated to equalize gas pressure for all tumblers connected to single gas service Other gas using appliances should be c...

Страница 24: ...efer to Figure 10 IMPORTANT Do not connect the tumbler to any voltage or current other than that specified on the tumbler serial plate Heat Source Electrical Specs Wires Required and Terminal Block Co...

Страница 25: ...s of the terminal block L1 and L2 or L1 and N If the electrical service is 120 Volt connect the neutral wire to NEUTRAL The ground wire must be connected to the green ground screw located in the junct...

Страница 26: ...THE GAS LINE TO EITHER OF THE TUMBLERS IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER It will first be necessary to convert the gas burner orifice and gas valve Appropriate conver...

Страница 27: ...does not light open and close loading door again and restart the ignition cycle IMPORTANT The Instant Electronic Ignition system will attempt to light the gas by sparking for approximately 15 seconds...

Страница 28: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 26 Notes...

Страница 29: ...e tab on the door should contact the switch plunger and depress it enough to close the switch with an audible click Refer to Figure 13 3 If tab does not depress the switch plunger enough to operate th...

Страница 30: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Adjustments M412060 28 Figure 13 Door Tab TMB2163N Door Switch Front Serial Plate Location Figure 14 TMB2164N...

Страница 31: ...4 inches 45 to 57 mm If it does not adjust the loading door interlock Refer to the appropriate paragraph in the Adjustments section of this manual 5 Start the tumbler and check the burner flame 6 Loa...

Страница 32: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 30 Notes...

Страница 33: ...close lint drawer will result in the tumbler not starting 3 Open the loading door and load the cylinder with laundry The unit is designed for a 30 pound cotton load dry maximum load DO NOT overload O...

Страница 34: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT M412060 32 Notes...

Страница 35: ...r ensuring a tight fit and lock IMPORTANT Failure to lock lint drawer will result in the tumbler not starting Monthly Lubrication Motor bearings fan bearings cylinder bearings and cylinder roller bear...

Страница 36: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Preventive Maintenance Instructions M412060 34 Figure 15 TMB2165N...

Страница 37: ...e service replacement 4 Inspect the belt tensioning idler assembly The idler arm should move freely with considerable belt spring tension approximately 40 pounds and should not bind in any position be...

Страница 38: ...k and clean steam coils Steam Models Only Clean exhaust ducts Check flow of combustion air Check flow of ventilation air Check belt tension Check chain tension Six Month Maintenance DATES Check for lo...

Отзывы: