Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
53. TERMINAL BLOCK OR POWER CORD
a. Terminal Block:
(1.) While supporting the access panel, remove
two screws from bottom edge of access
panel. See Figure 7.
(2.) Gently lower the access panel to disengage
locators from bottom edge of front panel.
See Figure 7.
(3.) Remove two screws holding bottom tabs
on front panel to dryer side panels. See
Figure 35. Swing bottom of front panel
away from dryer far enough to disengage
hold-down clips and locators from cabinet
top.
(4.) Disconnect wires from door switch. See
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
(5.) Remove two cabinet hold-down screws.
See Figure 29.
(6.) Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets.
See Figure 30.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets, or
supported against wall behind the dryer.
(7.) Remove all wires from terminal block.
NOTE: Refer to appropriate wiring diagram when
rewiring terminal block.
(8.) Remove screw holding terminal block and
shield to rear bulkhead. See Figure 56.
Figure 56
CABINET
TOP
TERMINAL BLOCK
ATTACHING
SCREW
TERMINAL
BLOCK
D353SE3A